HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)

Table 103 SIM Reporting Option Operation (continued)
DescriptionItem
Report service level information as SIM.
ON: Report, OFF: Do not report
Service
The number of information levels to be reported as SIM.Num. of Types
Threshold Value Operation
Example 1
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Alter,Normal end,,,Seq.=xxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,Unrecd.),
Read/Write error(Recovered,Unrecd.),Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),FC I/F error Port 0(Unrecd.),
FC I/F error Port 1(Unrecd.),Port 0 error(Unrecd.),Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDDR00-01,HDDR00-02,(snip)],Num. of PDEVs=1152
Example 2
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Error Reset,Normal end,,,Seq.=xxxxx
+PDEV=HDDR00-01
[Information]
Information function
Threshold Value
Threshold Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the parameters shown in Table 104 (page 109).
Table 104 Parameters for Threshold Value Operation
DescriptionParameter
Change the threshold of failed PDEV (physical device).Alter
Indicates Error Reset.Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 105 (page 109).
Table 105 Threshold Value Operation (Example 1)
DescriptionItem
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
7 days: 7 days, Total: Every operating days
Type
The threshold of Mechanical error.Mechanical error
(Recovered,Unrecd.)
The threshold of Media error.Media error
(Recovered,Unrecd.)
Threshold Value Operation 109