HP StorageWorks XP24000/XP20000 Audit Log Reference Guide (AE131-96085, May 2011)
Information function
ORM Value
ORM Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the following parameters, as shown in Table 100 (page 107).
Table 100 Parameters for ORM Value Operation
DescriptionParameter
Change the threshold of ORM (Online Read Margin).Alter
Indicates Error Reset.Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in Table 101 (page 107).
Table 101 ORM Value Operation
DescriptionItem
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
Today: Current day only, 7 days: 7 days, Total: Every operating days
Type
The threshold of Read Error (Unrecovered).Read Err.
(Unrecovered)
The threshold of Read Error (Recovered).Read Err.
(Recovered)
The threshold of Seek Error (Recovered).Seek Err.
(Recovered)
The threshold of Seek Error (Unrecovered).Seek Err.
(Unrecovered)
The threshold of Not Ready.Not Ready
The threshold of Other Errors.Other Errors
The threshold of Total Defect Count.Total Defect Count
The mounting location of the PDEV (physical device) which is the target of Alter or error
reset.
PDEV
The number of PDEVs (physical devices).Num. of PDEVs
SIM Complete Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],SIM Complete,,Normal end,,,Seq.=xxxxx
+Reference Code=[XXXXXX,XXXXXX,(snip)],Num. of Reference Codes=256
[Information]
Information function
SIM Complete
Service Information Message (SIM) Complete operation
SIM Complete Operation 107