Table 39 Combin ations of Parameters for the FCW ITHDR C o m m a n d (Version 2)
Combination
Parameters
SDEVN
TDEVN DEVN
DDSW XTNTLST ACTION
Source
Target
Case 1 (section
Case 1: TDEVN
Specied, DDSW
=NO on page 86)
Not
specied
Specied
Not
specied
NO
Not
specied
Not
specied
Not
specied
Case 2 (section
Case 2: TDEVN
Specied, DDSW
=NO, XTNTLST
Parameter
Specied on page
86)
Not
specied
Specied
Not
specied
NO
Specied Specied
Not
specied
Case 3 (section
Case 3: SDEVN
and
TDEVN
Specied, DDSW
=NO on page 88)
Specied Specied
Not
specied
NO
Not
specied
Not
specied
Not
specied
Case 4 (section
Case 4: SDEVN
and
TDEVN
Specied, DDSW
=NO, XTNTLST
Parameter
Specied on page
90)
Specied Specied
Not
specied
NO
Specied Specied
Not
specied
Case 5 (section
Case 5: SDEVN
and
TDEVN
Specied, DDSW
=YES on page 93)
Specied
Specied
or not
specied
Not
specied
YES
Not
specied
Not
specied
Not
specied
Case 6 (section
Case 6: SDEVN
and
TDEVN
Specied, DDSW
=YES, XTNTLST
Parameter
Specied on page
94)
Specied
Specied
or not
specied
Not
specied
YES
Specied Specied
Not
specied
Case 7 (section
Case 7: DEVN
Specied, ACTION
=THAW on page
95)
Not
specied
Not
specied
Specied
NO
Not
specied
Not
specied
THAW
Note:
The information specied by the XTNTLST parameter is supported only when the following
conditions are fully met:
The information specied by the XTNTLST parameter must be for both the source and target. If the
information specied by the XTNTLST parameter is only for one of the two, the copy operation
will result in an error.
Thesizeofthe specied copy source and target extents must be the same.
WA RN ING:
When the relationships a re withdrawn by the FCW ITHDR comma nd executed with the
DDSW parameter set to NO or without setting the D DSW parameter, the data integrity of the T-VOL
cannot
be guaranteed.