HP StorageWorks XP24000 Continuous Access Software User and Reference Guide, v01 (T5278-96002, June 2007)
Asynchronous pairs, you can use the Delete Range-Group option to rele ase all pairs in a group
using just one operation. Verify that the pair status has changed to SMPL for all Continuous
Access volumes b efore continuing.
2. Delete the Continuous Access Asynchronous g roup(s) from the MCU(s) (see
“Deleting Consistency Groups” on page 89). The RCU will automatically delete a group when
all pairs in the group have been released.
3.
Delete the RCUs (see “Deleting an RCU” on page 82). Check each CU of each MCU to make
sure that all RCUs have been deleted before continuing.
4. Remove the remote copy connections (physical paths) . If you are not familiar with the operation
for the remote copy hardware components (for example, switches) , call HP technical support
for assistance.
5. Reconfigure the storage system ports as needed (for example, reset the initiator ports to ordinary
target ports at the MCUs) (see “Configuring the Host Inter face Ports”onpage70).
98
Performing Continuous Access Configuration Operations