HP StorageWorks XP24000 Continuous Access Software User and Reference Guide, v01 (T5278-96002, June 2007)

Path Status
Description Corrective Action
Invalid Port
The specied port is not congured as an
initiator port, or this path a lready exists.
Make sure the correct MCU port is
congured as an initiator por t and the
correct RCU port is congured as an RCU
target port.
Make sure that you entered the correct
RCU S/N and SSID and path parameters
(port, link address, logical address).
Delete the failed path. You may need
to
change the minimum paths setting or
delete the RCU in order to delete the path.
Then add the path/RCU using Edit Path
or
Add RCU.
Port number
invalid
The specie
d
port number is invalid. The
cable is no
t
connected to the specied
port.
Delete the failed path. Check the port
number, or the cable connection and retry.
Fibre remote
copy is not
supported.
The microcode on the RCU side does not
support the breremotecopy function.
Install the microcode that supports the bre
remote copy function on the RCU side.
Communication
err or
A timeout error has occurred between the
MCU and RCU.
Delete th e failed p ath and retry.
RCU Port
Number
Mismatch
The spe
cied port in the RCU is physically
discon
nected from the MCU.
Make sure that you entered the correct
RCUportnumber. Correctthe port number
if
necessary.
Make sure that the MCU and RCU are
physically connected.
Make sure that the Fibre Channel topology
settin
gs for the MCU and RCU ports are
corre
ct.
RCU P ort Type
Mismatch
The specied RCU port is not c ongured
as an RCU target port.
Make sure that the RCU port is congured
as an
RCU target port.
Communication
Failed
The MCU connected to the RCU
successfully, but a logical communications
timeout
occurred.
Make sure that the RCU port and remote
copy connection hardware (cables and
switches) are properly congured and
functioning.
138