HP StorageWorks XP Remote Web Console User Guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (T1714-96031, June 2010)

Figure 108 Sample Configuration Definitions
.
Comments
You can also type comment rows in the spreadsheet by beginning a row with the # character. The
comment row can consists of any characters in any language. A row that includes only a linefeed
code is also recognized as a comment row.
Example:
# (comment)
# Change CHA settings (comment)
[CHA](function tag)
# CHA,PCB Mode (comment)
# (linefeed)
# (linefeed)
CHA-1P,Standard (indicating changes)
CHA-1Q,Standard (indicating changes)
New Settings Can Affect Other Settings
As a general rule, the settings are applied to the array one at a time, in the order they appear in the
spreadsheet. This means that the settings of the prior function tags can affect the following function
tags. For example, if you were to delete a host group in the [HostGroup] tag, the path settings related
to the deleted host group would also be automatically deleted. If you then write the new settings for
the automatically deleted path in the [LUN] tag or the [WWN] tag, that would cause an error.
LUN Manager Spreadsheet Settings
The following LUN Manager functions can be defined by using Configuration File Loader:
Channel Adapter (CHA) settings allow you to change the PCB mode. See Setting the CHA
Mode on page 152.
Port Settings allow you to change the settings for arbitrated loop-physical address (AL-PA), data
transfer speed (host speed), and topology. You can also change the Secure Manager XP setting.
See Port Settings on page 153.
Host Group Settings allow you to create, delete, or change the host group. See Setting the Host
Group on page 154.
Configuration File Loader150