First Error Check
The rst error check is performed when the spreadsheet le is imported. The rst error check veries
that the spreadsheet is properly formatted. If an error occurs, the spreadsheet is rejected, and an error
message is displayed. Errors detected at the rst check include the following:
The rst row of the spreadsheet (the declaration line) is not correctly written, or the
stated product is not installed. For more information on the declaration line, see
Spreadsheet Declarationon page 148.
The spreadsheet le is not in text le format (the le is a binary le).
There is no function tag in the spreadsheet. For more information on the function tag, see
Function Tags”onpage148.
The le name is incorrect (e.g., the extension is not .spd”, or the le name exceeds the maximum
number of letters).
The number of letters in a row exceeds 128.
The number of rows in a spreadsheet exceeds 400,000.
166