HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 72 Error Codes Part Code 8505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iContact the storage
administrator. (To the storage
administrator: reconfigure the
login information.) If this
problem persists, call
technical support.
The login information for the
partition management
function has been initialized
due to detection of conflicting
information. Contact the
storage administrator. (To the
storage administrator:
reconfigure the login
information.)
565018505
4WThe operation to set the
maximum number of
connections has been
cancelled because an attempt
was made to specify a value
that is less than the number
of users who are currently
connected. Check the
maximum permissible number
of connections.
The operation to set the
maximum number of
connections has been
cancelled because an attempt
has been made to specify this
value to less than the number
of users who are currently
connected. Check the
maximum permissible number
of connections.
565028505
3ESelect another window. To
set this function, contact the
storage administrator.
This function cannot be used
by the storage partition
administrator.
565248505
5WConfirm that no user is
logged into XP Remote Web
Console, and then retry the
operation.
While another user is logged
into XP Remote Web
Console, you cannot edit the
information for the SLPR that
the user owns. SLPR No:%s
565278505
0WCorrect the licensed capacity
on the License Key Partition
Definition window.
The licensed capacity was
exceeded because of
changing the configuration.
Correct the licensed capacity
on the License Key Partition
Definition window.
565368505
4EIf this problem persists, call
technical support.
An unknown error was
detected.
570028505
6WIf this problem persists, call
technical support.
Some of the shared memory
of the subsystem may be
blocked, or the subsystem is
being maintained. Check the
status of the subsystem. If this
problem persists, call
technical support.
583108505
6WIf this problem persists, call
technical support.
Some of the cache memory
of the subsystem may be
blocked, or the subsystem is
being maintained. Check the
status of the subsystem. If this
problem persists, call
technical support.
583118505
5iWait until the write pending
rate falls, and then retry the
operation.
The configuration cannot be
changed because the write
pending rate of the intended
CLPR is too high. Wait until
the write pending rate falls,
and then retry the operation.
583128505
XP Remote Web Console Error Codes 343