HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 52 Error Codes Part Code 6505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
0WCheck the status of the
specified secondary data
volume.
The operation to change the
status to the status ready for
Delta resync failed. The
specified secondary data
volume should meet the
following requirements.
The specified volume is a
secondary data volume of
another mirror.
The pair status of the
specified volume is PAIR
or Duplex.
587006505
0WDelta resync cannot be
executed. Delete the pair
ready for Delta resync and
copy all data in the primary
data volume.
The Delta resync operation
failed because journal data
of the master journal group
was insufficient.
587016505
0WCheck the number of pairs for
each mirror of the restore
journal group.
The Delta resync operation
failed because the number of
pairs for each mirror of the
restore journal group was
different.
587026505
0WDelta resync cannot be
executed. Delete the pair
ready for Delta resync and
copy all data in the primary
data volume.
The Delta resync operation
failed because the secondary
data volume was updated.
587036505
0WCheck the status of the data
volumes in the Continuous
Access, Hitachi TrueCopy for
z/OS, XP Continuous Access
Journal or the Hitachi
Universal Replicator for z/OS
window.
The operation to change the
status ready for Delta resync
failed because the status of
the volumes was one of the
following:
The P-VOL for Continuous
Access Synchronous and
the primary data volume
for XP Continuous Access
Journal are different.
The M-VOL for Hitachi
TrueCopy for z/OS
Synchronous and the
primary data volume for
Hitachi Universal
Replicator for z/OS are
different.
587046505
0WCheck the status of the
specified secondary data
volume.
The Delta resync operation
failed. The specified
secondary data volume
should meet the following
requirements.
The specified volume is a
secondary data volume of
another mirror.
The pair status of the
specified volume is PSUS,
PSUE, Suspend, PAIR or
Duplex.
587056505
256 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes