HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 3 Error Codes Part Code 0003 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
2EIf this problem persists, call
technical support.
An error occurred during SVP
processing. If this problem
persists, call technical
support.
11030003
2EIf this problem persists, call
technical support.
An error occurred during SVP
processing. If this problem
persists, call technical
support.
11040003
2EIf this problem persists, call
technical support.
An error occurred during SVP
processing. If this problem
persists, call technical
support.
11050003
2ECommand device setting is
requested for Reserve volume
of XP Auto LUN/On Demand
volume. Or it is requested for
volumes other than open
volumes (including
un-installed volumes.) The
error does not occur normally
because it is guarded in the
screen. Contact the program
maker.
When changing the
configuration of the
command device, you cannot
set the command device to
the following volumes:
Reserved volumes for XP
Auto LUN
Just-in-Time volumes
Volumes other than the
open-system volumes
(including unmounted
volumes.)
11080003
2EIf this problem persists, call
technical support.
An error occurred. If this
problem persists, call
technical support.
11100003
2EA nickname is not specified
when the configuration
change of XP LUN
Configuration and Security
Manager Software is
requested. The error does not
occur normally because it is
guarded in the screen.
Contact the program maker.
An error occurred. If this
problem persists, call
technical support.
11110003
6EAfter changing the volume
which creates CV in VLL
operation, retry the VLL
operation.
The specified volume is
currently used by Parallel
Access Volume and is not
available for VLL operation.
11130003
2EYou have not specified the
value when registering
WWN. Or zero is set as the
WWN value. The error does
not occur normally because
it is guarded in the screen.
Contact the program maker.
An error occurred. If this
problem persists, call
technical support.
11160003
6EThe Configuration information
has been already changed.
Check the settings and
request the setting of the
configuration information
again.
Command device security
cannot be set to the specified
volume because the volume
is not a command device.
11230003
XP Remote Web Console Error Codes 23