HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 52 Error Codes Part Code 6505 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
5EIf the same error occurs
despite retrying, call technical
support.
This error code is not
registered.
73106505
3ERetry the operation. If this
problem persists, call
technical support.
An error occurred during SVP
processing. If this problem
persists, call technical
support.
80006505
3EWait for a while, and then
retry the operation.
A communication time-out
error occurred in the
subsystem. Wait for a while,
and then retry the operation.
80016505
3EWait for a while, and then
retry the operation.
A communication time-out
error occurred in the
subsystem. Wait for a while,
and then retry the operation.
80026505
2ERetry the operation. If this
problem persists, call
technical support.
An error occurred during SVP
processing. If this problem
persists, call technical
support.
81006505
3ECheck the DKCMAIN
microcode version and the
SVP microcode version,
because these versions might
be mismatched.
This function is not supported.81026505
4iRetry the operation.Retry operation.87006505
4iCheck the path status and
edit the path again.
The logical path between the
local and the remote
subsystems is invalid.
87016505
4iRefresh and check the
window. If possible, retry the
operation on the primary
data volume.
The status of the primary data
volume is not valid.
87026505
4iCheck the number of paths.The specified number of
paths is less than the
minimum number of paths in
the DKC Option window.
87036505
4WCheck the path status in the
DKC Status window, and
then restore the paths.
The specified number of
paths is less than the
minimum number of paths in
the DKC Option window, due
to a communication error
between the local and the
remote subsystems.
87046505
4WCheck the CHIP status on the
window. If the CHIP is
blocked, replace the CHIP,
and then retry the operation.
The path could not be deleted
due to a communication error
between the local and the
remote subsystems.
87056505
4iEnter the correct data.Parameter specified by
Continuous Access operation
is invalid.
87066505
220 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes