HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 48 Error Codes Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4WCheck the microcode version
of the RCU.
The Paircreate operation
failed. The version of the
specified RCU does not
support Continuous Access
with the NAS volume.
89366005
4WDelete all the pairs with the
serial XP Continuous Access
connection in the specified
MCU, and then retry the
operation.
The Paircreate operation with
the Fibre Channel XP
Continuous Access
connection failed because
there are pairs with the serial
XP Continuous Access
connection in the specified
MCU.
89376005
4WDelete all the pairs with the
Fibre Channel XP Continuous
Access connection in the
specified MCU, and then
retry the operation.
The Paircreate operation with
the serial XP Continuous
Access connection failed
because there are pairs with
the Fibre Channel XP
Continuous Access
connection in the specified
MCU.
89386005
4WCheck the LUN of the
specified M-VOL by using
RAID Manager, and specify
the LUN with the value less
than 1,024 for the M-VOL.
The specified M-VOL cannot
be used.
89396005
4iConfirm the status of the
specified R-VOL.
The operation failed because
the specified R-VOL is in a
Read Only status by Volume
Retention Manager.
89406005
4iRefresh the window a few
minutes later and check the
status of the specified volume
and other volume(s) of the
same group in the RCU. If it
is possible to perform
operations on the volume(s),
retry the operation.
The specified volume or other
volume(s) of the same group
in the RCU is being changed
to Simplex/Suspend status.
Retry the operation a few
minutes later.
89436005
4iCheck the status of the
specified R-VOL.
The specified R-VOL is not
available according to the
attribute of the R-VOL
changed by XP LUN Security
Extension Software.
89446005
4WVerify whether the
parameters of M-VOL, for
example, CU number, port,
GID and LUN, are supported
with the RCU microcode
program version or not.
Verify whether the SSID and
CU number of RCU and the
parameters of R-VOL, for
example, Port, GID and LUN,
are correct or not. And then,
retry the operation with the
correct parameters.
At least one of the following
is invalid:
M-VOL parameters (CU
number, Port, GID, LUN)
SSID or CU number of the
RCU
R-VOL parameters (Port,
GID, LUN)
89456005
XP Remote Web Console Error Codes 203