HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 48 Error Codes Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iThe delete pair (Pairsplit-S)
operation failed. A few
minutes later, refresh the
screen, confirm if the
specified volumes are in the
permissible status, and then
retry the operation.
Wait a few minutes and retry
the Delete Pair (Pairsplit-S)
operation.
88626005
4EThe XP Remote Control
computer detected an
unknown error code. Call
technical support.
Unknown Error Code.88636005
4ECall technical support.An internal error occurred.88646005
4ECall technical support.An internal error occurred.88656005
4ECall technical support.An internal error occurred.88666005
4ECall technical support.An internal error occurred.88676005
4EThe operation failed because
a duplicate CT Group is
already active in the MCU.
Verify the status of the CT
group and retry the
operation.
Duplicate CT Group# (A CT
Group has been already
active in MCU.)
88686005
4EVerify that the CT group is
active in the MCU.
CT Group is not active.88696005
4iThe group operation failed
because the specified group
has at least one
asynchronous pair. Renew
and check the Continuous
Access screen.
CT Group Option cannot be
changed unless all
asynchronous pairs in the
group are suspended or
deleted.
88706005
4iInstall TrueCopy
Asynchronous for Mainframe
in the MCU and retry the
operation.
The TrueCopy Asynchronous
for Mainframe function is not
installed in the specified
MCU.
88716005
4iThis microcode version does
not support multiple CT
Groups in the MCU. Verify
the status and retry the
operation.
This version does not support
multi CT Groups in the MCU.
88726005
4iInstall the XP Continuous
Access Asynchronous
Software function in the
MCU, and then retry the
operation.
XP Continuous Access
Asynchronous Software
function is not installed in the
specified MCU.
88736005
4iSpecify Local or None for the
timer type on the Continuous
Access window, and then
retry the operation.
Invalid Timer Type option.88746005
4ERenew and check the
Continuous Access screen.
At least one asynchronous
pair is active in this group.
88756005
4iConfirm the PCB type and try
the operation again with a
correct parameter.
There are no PCBs which
corresponds to the specified
port type.
88766005
198 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes