HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)
Table 48 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iThe option must be installed
in the MCU and RCU before
a volume pair can be
created.
Hitachi TrueCopy for z/OS
function is not installed in the
specified controller.
87816005
4iThe data migration option
must be installed in the
specified MCU before a data
migration pair can be
created.
Data Migration function is not
installed in specified
controller.
87826005
4iInstall the XP Continuous
Access Semi-Sync option in
the MCU and RCU, and then
retry the operation.
The XP Continuous Access
Semi-Sync function is not
installed in specified
controller(s.)
87836005
4iInstall the XP Continuous
Access Semi-Sync option in
the MCU and RCU, and then
retry the operation.
The XP Continuous Access
Semi-Sync function is not
installed in specified
controller(s.)
87846005
4iRecheck the volume.The M-VOL is defined as the
expansion volume.
87856005
4iRecheck the volume.The R-VOL is defined as the
expansion volume.
87866005
4iThe controller type or the
microcode version of the
specified RCU does not
support XP Continuous Access
for the expansion volume.
The specified RCU does not
support the XP Continuous
Access for the expansion
volume.
87876005
4iCheck the Port, G-ID and
LUN settings of the RCU. Or,
by referring to the OPEN
platform section in the
maintenance manual, check
whether the device emulation
type of the R-VOL is
supported or not.
The specified expanded
volume in the RCU is not
defined. Or, the device
emulation type of the R-VOL
is not the type that can be
used for XP Continuous
Access operations performed
via the serial interface.
87886005
4iThe combination of the
specified volumes for Volume
Management is not valid.
Verify the parameters and
retry the operation.
Combination of the specified
expansion volumes is not
valid.
87896005
4iConfirm the status of the
specified expansion volume
and microcode version of the
RCU.
The specified expansion
volume (Port/GID/LUN) of
the RCU is not usable.
87906005
4iVary the concerned path
offline from the other host,
and then retry the operation.
The specified M-VOL is still
online from another HOST.
87916005
4iInstall the Volume Retention
Manager in the MCU and the
RCU, and then retry the
operation.
Add Pair operation failed
because the Volume Retention
Manager function is not
installed in the specified RCU.
Install Volume Retention
Manager, and retry the
operation.
87926005
XP Remote Web Console Error Codes 189