HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)
Table 48 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iThe MCU NVS status
specified by the host is not
active. Set the NVS to on for
the MCU, using any attached
host, and then retry the
operation.
NVS status of MCU is not
active.
87396005
4iThe RCU NVS status specified
by the host is not active. Use
any attached host to set the
NVS to on for the MCU, and
then retry the operation.
NVS status of RCU is not
active.
87406005
4iCheck the path status
between the MCU and the
RCU.
The logical paths between the
MCU and RCU are not
established.
87416005
4WCheck the status of the
M-VOL tracks, and clear the
pinned tracks.
Pinned track(s) exists on the
M-VOL.
87426005
4WCheck the status of the R-VOL
tracks, and clear the pinned
tracks.
Pinned track(s) exists on the
R-VOL.
87436005
4WThe M-VOL is not available
for the requested operation,
because of one or more of
the following reasons:
1. The volume is blocked.
2. The volume is under
maintenance.
3. The volume is copying
data (correction copy or
drive copy.)
4. The volume is correction
access condition. Check
the logical device status of
the specified M-VOL. If the
M-VOL is either under
maintenance or is copying
data, retry the operation
after the process is
completed.
The specified M-VOL
condition is not valid for XP
Continuous Access.
87446005
184 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes