HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 48 Error Codes Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iAdd the normal path(s), and
then set the minimum number
of paths.
The number of minimum
paths exceeds the number of
normal paths.
87276005
4iTake either of the following
actions:
1. Add normal paths, and
then delete the paths.
2. Decrease the number of
minimum paths, and then
delete the paths.
The number of minimum
paths exceeds the number of
normal paths.
87286005
4ECall technical support.An internal error occurred.87296005
4i1. If you are adding RCUs,
specify the same logical
address.
2. If you are editing paths,
specify the same logical
address as the existing
paths. (See the Edit Path
Screen.)
Invalid Logical Addresses are
specified.
87306005
4iThe logical addresses of all
existing paths are not the
same. Delete the RCU, and
then re-add it, using the same
logical address as other
existing paths.
The existing logical addresses
are not equal.
87316005
4EThe maximum number of
SSIDs (four) has been
entered. Verify that the SSIDs
are valid, delete one or more,
and then retry the operation.
Too many SSIDs (Only Four
SSIDs are allowed.)
87326005
4iInstall the program product
key in the MCU.
The Fibre-XP Continuous
Access function is not
installed in the specified
MCU.
87336005
4iInstall the program product
key in the RCU.
The Fibre-XP Continuous
Access function is not
installed in the specified RCU.
87346005
4ECheck the serial number,
SSID and link address of the
RCU, and set the correct
value. Then retry the
operation. If the same error
occurs, call technical support.
Invalid RCU serial number,
SSID, Link Address or
Controller ID.
87356005
4iDelete all XP Continuous
Access volume pairs of the
specified RCU or SSID, and
retry the operation.
The specified RCU or SSID
contains some XP Continuous
Access volume pairs.
87366005
4ECall technical support.An internal error occurred.87376005
4iThe emulation type of the
MCU does not support XP
Continuous Access. To use XP
Continuous Access, call
technical support.
XP Continuous Access is not
supported under the MCU
Controller emulation type.
87386005
XP Remote Web Console Error Codes 183