HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)
Table 48 Error Codes — Part Code 6005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
4iIt takes time for the change
processing of pair status.
Wait for a while, and then
refresh the screen and
confirm the pair status has
been changed properly. If the
pair status is not changed,
check the MCU/RCU
configuration and the
condition of the paths
between the CUs.
It takes time for the change
processing of pair status.
Wait for a while, and then
refresh the screen and
confirm the pair status has
been changed properly. If the
pair status is not changed,
check the MCU/RCU
configuration and the
condition of the paths
between the CUs.
81046005
4iRetry the operation.Retry operation.87006005
4iA logical path does not exist
between the MCU and the
RCU. Check the path status
on RCU Status screen, and
reestablish the paths with Edit
Path.
Logical Path between the
MCU and the RCU is not
active.
87016005
4iThe pair status is not a
permissible type for this
operation. Renew and check
the screen. If the M-VOL
status permits the operation,
retry the operation.
The pair status of the M-VOL
is not valid.
87026005
4iThe number of paths is less
than the minimum number
specified on the RCU Option
screen. Check the number of
paths, establish the minimum
number of paths, and retry
the operation.
The specified number of Paths
is less than the Minimum
number of Paths on RCU
Option screen.
87036005
4WCheck the paths status on the
RCU Status screen, and
reestablish the paths on the
Edit Path screen. See the
OPENPLATFORM SECTION
in the maintenance manual
to confirm whether the device
emulation type of the R-VOL
is supported by XP
Continuous Access via serial
interface.
The specified number of
paths is less than the
minimum number of paths on
the RCU option screen due to
a communication error
between the MCU and the
RCU, or the device emulation
type of the R-VOL is not
supported by XP Continuous
Access via serial interface.
87046005
4WEither a communication error
occurred between the MCU
and the RCU, or the CHIP has
become blocked. Call
technical support.
The path could not be deleted
due to a communication error
between MCU and RCU.
87056005
4iA parameter specified by the
XP Continuous Access
operation is invalid. For
example, the R-VOL that is
specified could already be in
use as the R-VOL of another
XP Continuous Access pair.
Parameter specified by XP
Continuous Access operation
is invalid.
87066005
180 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes