HP StorageWorks XP Remote Web Console Error Codes: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (AE002-96057, May 2011)

Table 37 Error Codes Part Code 4005 (continued)
Failure
Level
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
6WSet the prestaging area by
using XP Cache LUN
Software to use the
prestaging function.
The prestaging is not
executed because the
prestaging area does not
exist. Check the XP Cache
LUN Software setting.
565424005
6EWait for a while, and then
retry the operation.
The current XP Cache LUN
Software setting cannot be
changed because the sidefile
size exceeds the threshold.
585114005
6EWait for a while, and then
retry the operation.
The current XP Cache LUN
Software setting cannot be
changed because the
prestaging operation is in
progress. Wait for a while,
and then retry the operation.
585124005
6EWait for a while, refresh the
window, and then retry the
configuration operation. Or
check the status of the disk
storage system to find
whether the storage system is
blocked or not. If the problem
persists, contact your HP
account support
representative.
Prestaging not completed.585134005
2ECall technical support.Currently running microcode
version does not support the
specified operation.
585144005
6WWait for a while, and then
retry the operation.
A maintenance operation is
in progress. For example:
LDEV formatting is in
progress
Correction Copy is in
progress
Drive Copy is in progress
The CHIP/ACP status is
changing
The cache status is
changing
Replacement of an OEM
drive microcode is in
progress
LDEV shredding is in
progress
Extent shredding is in
progress
Therefore the specified
operation cannot be
executed.
587094005
XP Remote Web Console Error Codes 151