HP StorageWorks XP Remote Web Console Error Codes HP XP12000 Disk Array HP XP10000 Disk Array HP 200 Storage Virtualization System nl nl Abstract This guide lists the error codes and error messages that appear in the XP Remote Web Console window for HP StorageWorks XP disk arrays. Recommended actions are provided for most errors.
© Copyright 2007, 2011 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Contents 1 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes..................................................................................................4 Remote Web Console for Storage System Messages......................................................................4 Message Window Format..........................................................................................................4 XP Remote Web Console Error Codes........................................
1 HP StorageWorks XP Remote Web Console for Storage System Messages and Error Codes The term storage system in this guide refers to the following disk arrays: • HP StorageWorks XP12000 Disk Array • HP StorageWorks XP10000 Disk Array • HP StorageWorks 200 Storage Virtualization System Remote Web Console for Storage System Messages The following figure shows a typical message window displayed by XP Remote Web Console for XP software.
NOTE: Messages with a part code 60xx (where xx is a two-digit number) are Hitachi TrueCopy for z/OS or XP Continuous Access messages. This manual contains Hitachi TrueCopy for z/OS messages only. If you are an XP Continuous Access user, note that: ◦ The word M-VOL in Hitachi TrueCopy for z/OS messages is equivalent to P-VOL in XP Continuous Access messages. ◦ The word R-VOL in Hitachi TrueCopy for z/OS messages is equivalent to S-VOL in XP Continuous Access messages.
• 6: No change with refreshing automatically • 7: XP Remote Web Console is automatically switched to view mode. If necessary, change the mode to Modify. NOTE: The iSCSI function is planned for future support. Table 1 Error Codes — Part Code 0001 6 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0001 1000 An error occurred during SVP processing. If this problem persists, call technical support. If this problem persists call technical support.
Table 1 Error Codes — Part Code 0001 (continued) Part Code Error Number Error Message 0001 3001 0001 Recommended Action Severity Level Failure Level The number of set operations Reduce the number of set exceeds the maximum operations and perform (20000.) again. E 6 3002 An error occurred during SVP processing. If this problem persists, call technical support. If this problem persists call technical support. E 2 0001 4001 An error occurred during SVP processing.
Table 1 Error Codes — Part Code 0001 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0001 5075 An error occurred during SVP processing. If this problem persists, call technical support. If this problem persists, call technical support. W 2 0001 5099 An error occurred during SVP processing. If this problem persists, call technical support. If the same problem persists E despite retrying, call technical support.
Table 1 Error Codes — Part Code 0001 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0001 5516 An error occurred during SVP processing. If this problem persists, call technical support. If the same problem persists E despite retrying, call technical support. 2 0001 5517 An error occurred during SVP processing. If this problem persists, call technical support. If the same problem persists E despite retrying, call technical support.
Table 1 Error Codes — Part Code 0001 (continued) 10 Part Code Error Number Error Message Recommended Action 0001 5555 The password flag is invalid. The password flag is invalid. E Check the setting, and then Check the setting, and then retry the operation. retry the operation. 2 0001 5556 The password is invalid. Check the setting, and then retry the operation. E 2 0001 5557 The specified permission flag The specified permission flag E is invalid. Check the setting, is invalid.
Table 1 Error Codes — Part Code 0001 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0001 6002 An error occurred during SVP processing. If this problem persists, call technical support. If this problem persists, call technical support. E 2 0001 6004 An error occurred during SVP processing. If this problem persists, call technical support. If this problem persists, call technical support.
Table 1 Error Codes — Part Code 0001 (continued) 12 Part Code Error Number Error Message 0001 55231 0001 Recommended Action Severity Level Failure Level Applying operation Wait for a while, and then (operation of changing retry the operation. configuration) is in progress in the other SLPR. Applying operation (operation of changing configuration) cannot be performed simultaneously in the multiple SLPRs. E 10 56524 This function cannot be used Select another window.
Table 1 Error Codes — Part Code 0001 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0001 56556 Complete operation of SIMs failed because the number of audit logs that had not been transferred exceeded the threshold. Complete operation of SIMs E failed because the number of audit logs that had not been transferred exceeded the threshold. 5 0001 56557 The complete operation of the SIM may not have completed since the SVP is busy.
Table 2 Error Codes — Part Code 0002 (continued) 14 Part Code Error Number Error Message 0002 2008 0002 Recommended Action Severity Level Failure Level An error occurred during SVP If nothing changes despite processing. If this problem retrying, call technical persists, call technical support. support. E 3 2009 An error occurred during SVP If this problem persists call processing. If this problem technical support. persists, call technical support.
Table 2 Error Codes — Part Code 0002 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0002 5130 A sequence error occurred. Call the developer of the client program. Connection is terminated E from the server due to the network failure etc. Log on again. This error might occur and remain internally in the unlock function log when a user in View mode selects the Exit button, but this is not a problem. In other cases, call technical support.
Table 2 Error Codes — Part Code 0002 (continued) 16 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0002 6502 Now processing. Wait for a while, and then retry the operation. Log in again after a while. i 0 0002 6531 The SVP is busy. Wait for a while, and then retry the operation. If the same problem persists E despite retrying, call technical support. 3 0002 7030 An error occurred during SVP If this problem persists, call processing.
Table 2 Error Codes — Part Code 0002 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0002 56526 The resources of other SLPR(s) Correct the settings, and then E cannot be accessed. retry the operation. 6 0002 58578 An error occurred in the Select [All Refresh] and subsystem. The configuration refresh the configuration. may be inconsistent. Select [All Refresh] and refresh the configuration.
Table 3 Error Codes — Part Code 0003 (continued) 18 Part Code Error Number Error Message Recommended Action Severity Level 0003 1009 The emulation type of the volumes combined into a LUSE volume is not for open systems. The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 0003 1010 An error occurred during SVP If this problem persists, call processing. If this problem technical support.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 1021 An error occurred. If this problem persists, call technical support. The specified volume does E not exist. (You have specified wrong CU#:LDEV#) or the LDEV (exclusively for mainframe) cannot be processed in this agent. The error does not occur normally because it is guarded in the screen. Contact the program maker. 2 0003 1022 An error occurred.
Table 3 Error Codes — Part Code 0003 (continued) 20 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 1031 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 0003 1032 The specified extent is over the size which can be specified. Set the extent area within the E size which can be specified, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 1043 0003 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 1044 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 1063 The specified WWN is already in use. Specify another WWN. Correct the specified contents, and request the setting of the configuration information again. E 6 0003 1064 You are trying to register the same WWN as the already registered one. Check the settings and request the setting of the configuration information again.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 1103 0003 Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 1104 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action 0003 1124 The command device setting and the command device security setting are incorrect. You cannot do any of the following to the same volume: The setting method of E command device/command device security is incorrect. The following settings are invalid. 1. Set command device + Release command device security 2.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action 0003 1131 No more host groups can be set, because the number of host groups has reached the maximum (254) that can be set in a port. No more host groups can be E set, because the number of host groups has reached the maximum (254) that can be set in a port. Reduce the number of host groups, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) 26 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 1140 Because the Port Group setting is done, it is impossible to change. Release the Port Group setting. Release the Port Group setting. E 2 0003 1141 Processing in progress. Wait Log in again after a while. for a while, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 1171 0003 Recommended Action Severity Level Failure Level This LU cannot be combined Correct settings, and then into or released from a LUSE retry. volume because it is not a Read/Write enabled volume that is also usable as an S-VOL (secondary volume.) E 6 1172 The LUs cannot be combined Correct settings, and then or released because the retry. volumes don't have Read/Write attribute.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action 0003 1186 In the linkage operation including LUSE, the path is specified to other than the top. The Configuration information E has been already changed. You cannot expand the LU because the host mode of the group with paths which are defined in the LU is corresponding to online LUSE. The Configuration information E has been already changed.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 1198 Since a path is defined to an Correct the settings, and then E XP Flex Copy LU, you cannot retry. set high-speed mode. 6 0003 1199 When defining paths from Correct the settings, and then E iSCSI ports, you can only retry. define paths to open-systems volumes. 6 0003 1201 The selection of High Speed mode/MIX mode is invalid. The specified port cannot be changed to High Speed mode/MIX mode.
Table 3 Error Codes — Part Code 0003 (continued) 30 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 1354 You could not register the WWN to the initiator or external port. To register the WWN, change the attribute of the specified port to Target or RCU Target. E 6 0003 1355 You could not change the host mode of the host group that you connected to the initiator or external port.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 1367 0003 Recommended Action Severity Level Failure Level The host mode 4C is used for Check the settings, and then a host group connecting to retry. volumes that cannot be used for XP Ext Access Manager. E 6 1368 The host mode 4C can only be used with XP External Storage Software volumes. Check the settings, and then retry. E 6 0003 1600 This functionality is not available.
Table 3 Error Codes — Part Code 0003 (continued) 32 Part Code Error Number Error Message 0003 1910 0003 Recommended Action Severity Level Failure Level The specified volume contains Select another volume. XP Snapshot pairs. E 6 1911 The specified volume contains Select another volume. Pool-VOLs. E 6 0003 1912 The specified volume is a Correct the settings, and then E remote command device, and retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0003 2003 XP Auto LUN Software, QuickRestore, etc. are in process. After you reply to this message, a window that shows only the Refresh button will be displayed. Wait for a while, and then select [Refresh]. After you reply to this E message, a window that shows only the Refresh button will be displayed. Wait for a while, and then select [Refresh].
Table 3 Error Codes — Part Code 0003 (continued) 34 Part Code Error Number Error Message 0003 2013 0003 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 2014 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 2082 Processing is disabled because the host is mounted or the device is reserved. The host is mounted or the device is reserved. Unmount the host and cancel reservation of the device. If the host is an AIX host, unmount the host, and execute the varyoffvg command. E 6 0003 2083 The subsystem status is invalid. Call technical support.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0003 2090 The settings of XP Business Copy, Hitachi ShadowImage™ for z/OS, XP FlashCopy Mirror, or XP Flex Copy exist. Either release the settings or stop the I/Os, and then retry the operation. Either reset the settings or W stop the I/Os, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 2096 Currently running microcode version does not support the specified operation. An error occurred. If this E problem persists call technical support. 2 0003 2097 The host specified by the WWN is performing I/O operations. Stop executing I/Os, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action 0003 2204 Devices to be maintained Delete or suspend all pairs to E include journal volumes. which the journal volumes Delete or suspend all pairs to belong. which the journal volumes belong. 6 0003 2205 Devices to be maintained include journal volumes. Delete all pairs to which the journal volumes belong.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0003 2516 A XP Continuous Access, XP Continuous Access Journal, or Hitachi Universal Replicator for z/OS pair is defined. Cancel or suspend the pair definition, and then retry the operation. Cancel or suspend the pair definition, and then retry the operation.
Table 3 Error Codes — Part Code 0003 (continued) Part Code Error Number Error Message 0003 3002 0003 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 3003 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 4 Error Codes — Part Code 0004 (continued) Part Code Error Number Error Message 0004 6010 0004 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 6011 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 6 Error Codes — Part Code 0006 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0006 1005 An error occurred. If this problem persists, call technical support. Call technical support. E 2 0006 1006 An error occurred. If this problem persists, call technical support. Call technical support. E 2 0006 1007 An error occurred. If this problem persists, call technical support. Call technical support. E 2 0006 1008 An error occurred.
Table 7 Error Codes — Part Code 0007 (continued) Part Code Error Number Error Message 0007 5305 0007 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5306 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 8 Error Codes — Part Code 0010 Part Code Error Number Error Message 0010 4005 The user ID is already logged Since the same user name is W in. Do you want to log in being used, log in with the forcibly? other user name. 5 0010 6023 An error occurred during the Call technical support. process. If this problem persists, call technical support. E 2 0010 6026 The client system is illegal environment. E 2 0010 6027 A network error occurred.
Table 8 Error Codes — Part Code 0010 (continued) Part Code Error Number Error Message 0010 56000 0010 Recommended Action Severity Level Failure Level An error occurred during file Check the file status. reading. E 4 56001 An error occurred during the If this problem persists, call I/O processing of a technical support. temporary file. If this problem persists, call technical support.
Table 9 Error Codes — Part Code 0105 46 Part Code Error Number Error Message 0105 1904 0105 Recommended Action Severity Level Failure Level The specified volume cannot Select another volume. be assigned as a LUSE volume or a command device, and the path of the volume cannot be set because it is being used as a Pool volume. E 6 1905 There are virtual volumes and Select another volume. non-virtual volumes in the volumes specified to compose a LUSE volume.
Table 9 Error Codes — Part Code 0105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0105 2088 The XP Continuous Access pair is suspended. Add an alternate path. Add an alternate path. W 6 0105 2089 The corresponding CHIP Make sure that there is an W might contain the last path alternate path from the MCU. between the MCU and the RCU of XP Continuous Access. Make sure that there is an alternate path from the MCU.
Table 9 Error Codes — Part Code 0105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0105 2095 A maintenance operation is in progress. For example: Wait for a while and retry.
Table 9 Error Codes — Part Code 0105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0105 2205 Devices to be maintained include journal volumes. Delete all pairs to which the journal volumes belong. Delete all pairs to which the journal volumes belong. E 6 0105 2511 The restore operation has been failed, because the specified LDEV was not shredded or formatted. Shred or format the specified i LDEV.
Table 9 Error Codes — Part Code 0105 (continued) 50 Part Code Error Number Error Message Recommended Action Severity Level 0105 2519 An XP Business Copy or Hitachi ShadowImage for z/OS reserve volume is defined. Cancel the reserve volume, and then retry the operation. Cancel the reserve volume, E and then retry the operation. 6 0105 2520 An XP Auto LUN pair is defined. Cancel the pair definition, and then retry the operation. Cancel the pair definition, E and then retry the operation.
Table 9 Error Codes — Part Code 0105 (continued) Part Code Error Number Error Message 0105 6534 0105 Recommended Action Severity Level Failure Level The number of external Decrease the number of volumes that can be set to the external volumes and retry subsystem exceeds the the configuration operation. maximum. E 6 6535 You cannot make changes Delete a logical path, and because a logical path to the then make configuration volume still remains. changes.
Table 9 Error Codes — Part Code 0105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0105 58626 An XP Snapshot pair is defined. Cancel the pair definition, and then retry the operation. Cancel the pair definition, E and then retry the operation. 6 0105 58710 The specified volumes include remote command devices registered in the extended consistency group of Hitachi Universal Replicator for z/OS.
Table 10 Error Codes — Part Code 0110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0110 5085 The total physical (raw) disk Install additional license i capacity of the array exceeds key(s) to expand the license the installed licensed capacity of this software title. capacity. Install additional license key(s) to expand the license capacity of this software title. 5 0110 5086 The program product installation status has changed.
Table 10 Error Codes — Part Code 0110 (continued) 54 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0110 9002 The requested operation is complete. Select [OK]. i 5 0110 9100 Do you want to exit? i 0 0110 9101 Do you want to cancel? To cancel, press the OK button. i 0 0110 9102 Do you want to apply? To execute the operation in Preset, press the OK button.
Table 10 Error Codes — Part Code 0110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0110 57011 An error occurred regarding screen display. Log off from XP Remote Web Console. After that, log on to XP Remote Web Console again and check whether configuration changes have been made correctly. Log off from XP Remote Web E Console. After that, log on to XP Remote Web Console again and check whether configuration changes have been made correctly.
Table 11 Error Codes — Part Code 0190 (continued) 56 Part Code Error Number Error Message Recommended Action 0190 5011 The same nickname is already registered. Specify other nickname and register again. 0190 5012 Enter the nickname with up to 16 alphanumeric characters. Specify the nickname using up to 16 characters and less and retry. 0190 5013 Enter the product name with up to 16 alphanumeric characters. Specify the product name using up to 16 characters and less and retry.
Table 11 Error Codes — Part Code 0190 (continued) Part Code Error Number Error Message Recommended Action 0190 6011 Failed to open the storage list If the same error occurs again file. despite retrying, call technical support. 0190 6012 The storage list file does not exist. 0190 6013 Failed to back up the storage None. list file. 0190 6014 The user ID or password is invalid. 0190 6015 A permission error occurred.
Table 12 Error Codes — Part Code 0210 (continued) 58 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0210 55611 The specified user ID is already registered. Specify another user ID. W 5 0210 55612 The number of user accounts Delete unnecessary user exceeds the maximum. accounts. W 5 0210 55613 The specified current password is invalid. Specify a valid password. W 5 0210 55614 The specified password is invalid. Specify a valid password.
Table 12 Error Codes — Part Code 0210 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0210 55630 Do you want to cancel the instruction of deleting the user? To cancel the instruction of W deleting the user, select [OK]. Otherwise, select [Cancel]. 5 0210 55631 Enter a new password. Enter a new password. W 5 0210 55632 The length of the character Specify a valid password. string of the new password is invalid.
Table 13 Error Codes — Part Code 0290 (continued) 60 Part Code Error Number Error Message Recommended Action 0290 6030 Failed to open the user account list file. If the same error occurs again despite retrying, call technical support. 0290 6040 The user account list file does Call technical support. not exist. 0290 6050 Failed to open the backup file Call technical support. of the user account list. 0290 6060 Failed to back up the user account list file. Call technical support.
Table 13 Error Codes — Part Code 0290 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0290 6210 Failed to open the environment file. If the same error occurs again despite retrying, call technical support. 0290 6220 Failed to back up the environment file. Call technical support. 0290 6230 Failed to open the user account list file. Call technical support.
Table 14 Error Codes — Part Code 0305 62 Part Code Error Number Error Message 0305 6001 0305 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 7060 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 14 Error Codes — Part Code 0305 (continued) Part Code Error Number Error Message 0305 7209 0305 Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 7210 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 0305 56524 This function cannot be used Select another window.
Table 16 Error Codes — Part Code 0405 64 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0405 5013 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 0405 5047 An error occurred when installing or uninstalling the program product. Select the program product and select [Detail] to check the details on the error. 0405 5070 The product name is different.
Table 16 Error Codes — Part Code 0405 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0405 5073 To install/uninstall this program product, you must install/uninstall another program product first. Install the related program product first.
Table 16 Error Codes — Part Code 0405 (continued) Part Code Error Number Error Message Recommended Action 0405 5077 To uninstall this program product, you must uninstall another program product first. To uninstall this program W product, you should uninstall another program product first. 5 To uninstall this program W product, you should uninstall another program product first.
Table 16 Error Codes — Part Code 0405 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level TrueCopy Hitachi Asynchronous TrueCopy for for z/OS Mainframe Hitachi Hitachi Universal TrueCopy for Replicator for z/OS z/OS XP XP Continuous Continuous Access Access Asynchronous Software XP Continuous Access Journal Software XP Continuous Access FlashCopy Mirror Hitachi ShadowImage for z/OS FlashCopy Mirror Version 2 Hitachi ShadowImage for z/OS XP Snapshot X
Table 16 Error Codes — Part Code 0405 (continued) 68 Part Code Error Number Error Message Recommended Action 0405 5503 You have attempted to install an Emergency key to the option for which a Permanent key has been installed. To install the Emergency key forcibly by using the license key file, specify Only Normal & Warning and retry this operation. To install the Emergency key forcibly by using the license key code, select [OK].
Table 16 Error Codes — Part Code 0405 (continued) Part Code Error Number Error Message 0405 7064 0405 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 7101 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 16 Error Codes — Part Code 0405 (continued) 70 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0405 8003 The subsystem status is invalid. Call technical support. Isolate the abnormal section following the procedure below: 1. Rebooting the computer 2. Checking the LAN card/LAN cable 3. Checking the IP address of the computer 4. Replacing the computer 5.
Table 16 Error Codes — Part Code 0405 (continued) Part Code Error Number Error Message 0405 57092 0405 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 57093 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 18 Error Codes — Part Code 0410 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0410 5030 The displayed information has not been changed. Try again. Specify what you register, and retry. W 0 0410 5045 The length of key codes is 20. Correct the specified content, W and retry. 5 0410 5046 The maximum number of filename codes is 200. Correct the specified content, W and retry.
Table 18 Error Codes — Part Code 0410 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0410 59305 Total of licensed capacities cannot be set to 0 by deleting all licensed capacities individually. Set the licensed capacity so E that the total will not become 0. To make the total 0, execute Uninstall.
Table 19 Error Codes — Part Code 0505 (continued) Part Code Error Number Error Message 0505 6036 0505 Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 6040 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 19 Error Codes — Part Code 0505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0505 8001 An error occurred while connecting to the subsystem. Wait for a while, and then retry the operation. Retry the same operation several times. If this problem persists, call technical support. E 2 0505 8100 An error occurred while If the same problem persists E connecting to the subsystem.
Table 21 Error Codes — Part Code 0510 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0510 9010 There is a charge for this operation. Do you want to continue? To continue the operation, select the OK button. W 5 0510 59045 The detailed information will To continue processing, select W be initialized by this [OK]. To stop processing, operation. Do you want to select [Cancel].
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 2085 Copying is in progress for XP Wait for a while, and then Continuous Access, XP retry the operation. Business Copy, Hitachi ShadowImage for z/OS, XP Auto LUN, XP FlashCopy Mirror, or XP Flex Copy pairs. Wait for a while, and then retry the operation.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0605 2200 The Concurrent Copy or the Hitachi Extended Remote Copy for Mainframe operation is in progress in the target volumes.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 2516 An XP Continuous Access pair, an XP Continuous Access Journal pair, or a Hitachi Universal Replicator for z/OS pair is defined. Cancel or suspend the pair definition, and then retry the operation. Cancel or suspend the pair definition, and then retry the operation.
Table 22 Error Codes — Part Code 0605 (continued) 80 Part Code Error Number Error Message 0605 5099 0605 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5511 The program product is not installed. W 5 0605 5624 You cannot create a pair Correct the settings, and retry i because the specified volume the operation. is used as a NAS system volume.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message 0605 6533 0605 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 6534 The number of external Decrease the number of volumes that can be set to the external volumes and retry subsystem exceeds the the configuration operation. maximum.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message 0605 8140 0605 Recommended Action Severity Level Failure Level This logical volume cannot be Confirm and operate the selected because it is used as volume again. a volume for XP FlashCopy Mirror Version 2. E 5 8500 The program product is not installed. Install the program product. W 5 0605 8501 The command was rejected, because a status transition was in progress.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0605 8510 The M-VOL Suspend command was issued to a secondary boot device. Check the contents, and retry. W 5 0605 8511 You cannot reserve the volume, because a path group is set. Disconnect the R-VOL from the host, or delete the XP Continuous Access path.
Table 22 Error Codes — Part Code 0605 (continued) 84 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 8528 An internal logic error occurred. If the problem persists, call technical support. W 5 0605 8529 An internal logic error occurred. If the problem persists, call technical support. W 5 0605 8530 An internal logic error occurred. If the problem persists, call technical support. E 3 0605 8531 An internal logic error occurred.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 8954 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side. If this problem persists, call technical support. E 3 0605 8955 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side.
Table 22 Error Codes — Part Code 0605 (continued) 86 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 8967 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side. If this problem persists, call technical support. E 3 0605 8968 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 55314 The function tag (AddLU-PATH, AddLU-LDEV, or SetSSID) for executing processing is not in the spreadsheet. Check the contents of the XP External Storage Software spreadsheet. E 5 0605 55315 The function tag (AddLU-PATH, AddLU-LDEV, or SetSSID) for executing processing is duplicated in the spreadsheet.
Table 22 Error Codes — Part Code 0605 (continued) 88 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 55349 The number of LDEVs specified in the AddLU-LDEV tag does not match the number of LDEV IDs. Check the contents of the XP External Storage Software spreadsheet. E 5 0605 55370 The emulation type name is invalid. Check the contents of the XP External Storage Software spreadsheet.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 55385 The SSID value is not set. Check the contents of the XP External Storage Software spreadsheet. E 5 0605 55386 The number of paths registered for a port has reached the maximum. Check the contents of the XP External Storage Software spreadsheet.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level 0605 56512 Since the PCB for mainframe Add the PCB for mainframe, E is not installed, the Add and then retry the operation. Volume operation cannot be performed for the volumes of mainframe emulation types. 5 0605 56513 The specified emulation type is the type that cannot be added. To set the specified emulation type, the cache segment size must be changed.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 56520 The reserved volume setting of XP Auto LUN is defined. Release the reserved volume setting of XP Auto LUN, and then retry the operation. E 5 Increase the licensed E capacity for the program products that do not have sufficient licensed capacity, and then retry the operation.
Table 22 Error Codes — Part Code 0605 (continued) 92 Part Code Error Number Error Message Recommended Action 0605 58253 An external volume whose IO Specify an external volume E Suppression mode is set to whose IO Suppression mode Disable and an internal is set to Enable. volume are specified as the P-VOL and the S-VOL of the XP Flex Copy pair.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 58330 After Disconnect Subsystem Execute Check Path & Restore E or Disconnect Volume is Volume instead of Disconnect executed, neither Disconnect paths or Check paths. Paths nor Check paths can be executed. 5 0605 58331 The path requested by Disconnect paths or Check paths was not found. If this problem persists, call technical support.
Table 22 Error Codes — Part Code 0605 (continued) 94 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 58477 The operation cannot be performed, because the specified P-VOL is a virtual volume. Specify another volume. W 5 0605 58478 The operation cannot be performed, because the specified P-VOL is a pool volume. Release the pool volume or select another volume.
Table 22 Error Codes — Part Code 0605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0605 58623 The specified operation cannot be performed, because the XP Snapshot pair using the pool volumes to be maintained is in PSUS status or being restored. Resynchronize or release the E pair definition of the XP Snapshot pair using the pool volume to be maintained, and then retry the operation. 5 Cancel the pair definition, E and then retry the operation.
Table 23 Error Codes — Part Code 0607 (continued) Part Code Error Number Error Message 0607 6012 0607 6036 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 24 Error Codes — Part Code 0610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0610 59014 Have you performed the Disconnect operation? If you have performed the Disconnect operation, select [Yes]. If you have not performed the Disconnect operation, select [No]. To cancel the operation, select [Cancel]. i 0 0610 59015 The volume is mapped as a Select [OK]. mainframe volume by the Add LU operation. Format the volume before using it.
Table 24 Error Codes — Part Code 0610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0610 59044 No S-VOL can be assigned to the P-VOL. Check the volume. i 0 0610 59048 The P-VOL and the S-VOL To continue the operation, belong to different SLPRs. Do select the OK button. you want to continue this operation? i 0 0610 59055 The licensed capacity for a program product will become insufficient because of a configuration change.
Table 24 Error Codes — Part Code 0610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 0610 59065 No SSID can be specified. Check the SSID. i 0 0610 59066 Do you want to specify a CU To continue processing, select i without restrictions on SLPRs? [OK]. To stop processing, select [Cancel]. 0 0610 59107 The volume has been Select [OK]. mapped as a mainframe volume by the Add LU operation.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action 1005 1004 Multiple volumes are specified to a single port, group or LUN combination. The Configuration information E has been already changed. 1005 1005 Severity Level Failure Level 6 Check the settings and request the setting of the configuration information again. The following volumes cannot The Configuration information E be specified when you has been already changed.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1005 1015 LU path is set to the releasing expanded LU. (You need to release the expanded LU and path at the same time.) The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 1005 1018 An error occurred. If this problem persists, call technical support.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1005 1028 The number of volumes you intend to combine into a LUSE volume exceeds the maximum. The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 1005 1029 An error occurred during SVP If this problem persists, call processing. If this problem technical support.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action 1005 1067 You are trying to register the same host group number as the already registered one. The Configuration information E has been already changed. 1005 1068 Severity Level Failure Level 6 Check the settings and request the setting of the configuration information again. The specified host group has The Configuration information E not been registered. has been already changed.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1005 1125 There are no host groups where the WWN will be registered. The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 1005 1126 A volume set as a command Correct the specified E device cannot be used as a contents, and request again. component of a LUSE volume.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1005 1135 An error occurred. If this problem persists, call technical support. When PORT information E (Fibre Address/Fibre Topology/Channel Speed) is set, multiple change instructions are set to the same PORT. The error does not occur normally because it is guarded in the screen. Contact the program maker. 2 1005 1136 An error occurred.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message 1005 1151 1005 Recommended Action Severity Level Failure Level An error occurred. If this If this problem persists call problem persists call technical technical support. support. E 2 1170 The volume cannot be configured as a command device because the volume does not have Read/Write attribute. Correct settings, and then retry.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action 1005 1186 In the linkage operation including LUSE, the path is specified to other than the top. The Configuration information E has been already changed. You cannot expand the LU because the host mode of the group with paths which are defined in the LU is corresponding to online LUSE. The Configuration information E has been already changed.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action 1005 1203 High Speed mode/MIX mode was specified. However, there are addresses to which High Speed mode/MIX mode cannot be set in the Fibre Addresses of the specified ports. The Configuration information E has been already changed. High Speed mode/MIX mode was specified. However, there are topologies to which High Speed mode/MIX mode cannot be set in the topologies of the specified ports.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1005 1357 S-VOLs remain on the Fibre-RCU port. This operation may cause a fatal damage to the S-VOLs. Stop this operation. To continue this operation, remove the S-VOLs from the RCU port first. The specified Port is for Fibre E XP Continuous Access. Delete a logical path, and then retry the operation. 6 1005 1360 An XP Flex Copy volume cannot be defined as a system LU.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message 1005 1905 1005 Recommended Action Severity Level Failure Level There are virtual volumes and Select another volume. non-virtual volumes in the volumes specified to compose a LUSE volume. E 6 1906 The specified volume cannot Select another volume. be set as a command device because it is being used as a virtual volume.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message 1005 2013 1005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 2015 An error occurred while connecting to the subsystem. Wait for a while, and then retry the operation. A communication error occurs. If the same error occurs despite retrying, call technical support.
Table 26 Error Codes — Part Code 1005 (continued) 112 Part Code Error Number Error Message 1005 2500 1005 Recommended Action Severity Level Failure Level You cannot define paths from Correct settings and then NAS or iSCSI ports to retry. volumes that don't have Read/Write attribute. E 6 2501 The volume cannot be configured as a command device because the volume does not have Read/Write attribute. Correct settings, and then retry.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message 1005 6012 1005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 6036 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 26 Error Codes — Part Code 1005 (continued) 114 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1005 55558 The value of the iSCSI name is not specified or is set to zero. Check the setting. E 6 1005 55559 The specified package cannot be set because the package is for iSCSI. Check the setting. E 6 1005 55560 The fibre address, topology, channel speed, and Initiator/Target cannot be changed because the specified port is an iSCSI port.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1005 55572 The iSCSI name cannot be set because the number of iSCSI names exceeds the maximum that can be set in a port. Check the setting. E 6 1005 55573 The default nickname cannot Correct the settings, and then E be specified in the nickname retry the operation. setting of iSCSI name.
Table 26 Error Codes — Part Code 1005 (continued) Part Code Error Number Error Message 1005 58575 1005 58576 Recommended Action Severity Level Failure Level An error occurred while If this problem persists, call connecting to the subsystem. technical support. Wait for a while, and then retry the operation. E 6 A communication time-out If this problem persists, call error occurred in the technical support. subsystem. Wait for a while, and then retry the operation.
Table 27 Error Codes — Part Code 1010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1010 5053 No port is specified. Check the content of the operation. W 5 1010 5054 You must map at least one Check the content of the path to the command device. operation. W 5 1010 5056 The specified LUN does not exist in the system. Check the content of the operation. W 5 1010 5057 No LUN is specified. Check the content of the operation.
Table 27 Error Codes — Part Code 1010 (continued) 118 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1010 9015 The port of a PCB in High Speed mode/MIX mode is selected. When changing the parameter of topology or the parameter of host speed, the change will be applied to the PCB in High Speed mode/MIX mode. Are you sure you want to continue this operation? To change the parameter in High-Speed mode/MIX mode, select [OK]. Otherwise, select [Cancel].
Table 27 Error Codes — Part Code 1010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1010 59313 The iSNS IP address or the iSNS port number has been changed. Delete iSNS information and then select [Apply]. Select [OK]. W 5 1010 59314 Do you want to register the iSCSI port information in the iSNS server? To continue processing, select i [OK]. To stop processing, select [Cancel].
Table 28 Error Codes — Part Code 1110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1110 5022 Each area of the WWN should be 8 characters. Correct the specified content, W and retry. 1110 5040 The maximum number of Host You cannot register a host Groups is already registered. group. W 5 1110 5041 The maximum number of hosts is already registered. Reduce the number, and retry.
Table 28 Error Codes — Part Code 1110 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1110 5066 The corresponding port Check the operation contents. W cannot be changed because the security switch is OFF. 5 1110 5067 The corresponding port Check the operation contents. W cannot be changed because the port is an initiator port. 5 1110 5824 The specified iSCSI name is Enter a correct value, and incorrect. If the type of the retry.
Table 28 Error Codes — Part Code 1110 (continued) 122 Part Code Error Number Error Message 1110 9060 1110 Recommended Action Severity Level Failure Level The specified Host Group will be deleted. Do you want to continue? i 0 9061 The specified host will be deleted. Do you want to continue? i 0 1110 9063 Warning: The LU path to the LDEV will be released at once.
Table 28 Error Codes — Part Code 1110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1110 55545 The specified Target name is Correct the settings, and then W incorrect. If the type of the retry the operation. Target name is eui, specify the name in 20 characters. Failure Level 5 The characters can be any combinations of the following, starting with eui.
Table 28 Error Codes — Part Code 1110 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1110 59320 All iSCSI names not To continue processing, select i connected to iSCSI target will [Yes]. To stop processing, be deleted because these select [No]. names are unnecessary. The deleted iSCSI names will not be displayed. Are you sure you want to continue this operation? 5 1110 59336 The host is to be moved.
Table 29 Error Codes — Part Code 1205 (continued) Part Code Error Number Error Message Recommended Action Severity Level 1205 57100 An internal logic error is detected in the specified request. Call technical support. E (Obtain trace information by using the FD Dump tool.) 1205 58387 A communication error If the same problem persists W occurred while executing the despite retrying, check the contents of the setting. LAN setting between the SVP and the disk storage system.
Table 30 Error Codes — Part Code 1310 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 1310 5831 The target name is incorrect. Correct the settings, and then W retry the operation. 5 1310 5832 The user name is incorrect. Correct the settings, and then W retry the operation. 5 1310 5833 The secret is incorrect. Correct the settings, and then W retry the operation.
Table 31 Error Codes — Part Code 2010 (continued) Part Code Error Number Error Message 2010 5053 2010 Recommended Action Severity Level Failure Level You should map at least one Check the content of the path to LUSE volume. operation. W 5 5054 More than 36 volumes Check the content of the cannot be combined to form operation. a LUSE. W 5 2010 5055 The size of the LUSE volume exceeds 64,424,505,600 KB. Follow the correct operation procedure.
Table 31 Error Codes — Part Code 2010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 2010 55034 You are trying to combine To continue processing, select W volumes having different SLPR [OK]. To stop processing, numbers into a LUSE volume. select [Cancel]. If you perform this operation, the storage partition administrator will become unable to operate.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3005 2095 A maintenance operation is in progress. For example: Wait for a while and retry.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message 3005 7310 3005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 8001 A communication time-out If this problem persists, call error occurred in the technical support. subsystem. Wait for a while, and then retry the operation.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action 3005 55512 An error occurred during SVP If this problem persists, call processing. technical support. Severity Level Failure Level E 2 E 2 E 2 If this problem persists, call technical support. 3005 55513 An error occurred during SVP If this problem persists, call processing. technical support. If this problem persists, call technical support.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3005 56525 Because the settings across the multiple SLPRs are contained, the authority has been shifted to the storage administrator from the storage partition administrator. To continue the operation, contact the storage administrator. To perform other operations, select a function button.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3005 58468 The emulation type of the logical volume is incorrect. Specify another logical volume. E 6 3005 58469 The specified logical volume is being used by another program product. Specify another logical volume. E 6 3005 58470 The operation cannot be done, because the usage of the specified Pool is 100% (full.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3005 58472 Operation of the pool has failed. When the pool cannot be registered, do the following: E 6 Pool cannot be registered when: • check the installation status of the V-VOL management area, when the V-VOL management area is not initialized. Confirm the error message of E the logical volume(s) set as a Pool-VOL of the Pool.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level Check the amount of free space in Pool management block in the Pool window. Install additional shared memory if the free space is insufficient. E 6 An error occurred when setting the Pool. Confirm the error message of the logical volume(s) set as a Pool-VOL of the Pool.
Table 32 Error Codes — Part Code 3005 (continued) Part Code Error Number Error Message 3005 58576 3005 58706 Recommended Action Severity Level Failure Level A communication time-out If this problem persists, call error occurred in the technical support. subsystem. Wait for a while, and then retry the operation. E 3 An error occurred during SVP If this problem persists, call processing. technical support. E 2 Severity Level Failure Level If this problem persists, call technical support.
Table 33 Error Codes — Part Code 3010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3010 5054 Execute one of the following before deleting the LDEV: Check the content of the operation. W 5 Check the content of the operation. W 5 However, LDEV cannot be deleted for the Remote Command Device. • delete paths associated with the LDEV. • release the LUSE volume. • release the reserved volume of XP Auto LUN.
Table 33 Error Codes — Part Code 3010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3010 5058 Volume Initialize cannot be performed because the number of volumes that can be created in the parity group is exceeded. Reduce the number of volumes in the parity group, and then retry. W 5 3010 5060 Set the capacity of the volume used for VLL operation to 46 MB (96000 blocks) or more. Enter the correct value.
Table 33 Error Codes — Part Code 3010 (continued) Part Code Error Number Error Message Recommended Action Severity Level 3010 9019 There is no volume to recover To continue processing, select i in the specified parity group [OK]. To stop processing, (PG.) The CVs will be deleted select [Cancel]. from the PG. Is it OK? 0 3010 9060 Do you want to cancel Select [YES] for continuing making the following custom processing. Select [NO] if volume operation? you want to stop.
Table 33 Error Codes — Part Code 3010 (continued) Part Code Error Number Error Message 3010 55588 3010 Severity Level Failure Level No more V-VOLs can be set, Reduce the number of because the number of V-VOLs, and then retry the V-VOLs exceeds the maximum operation. number that can be set to the whole subsystem. W 5 55595 Only up to 16,384 LDEVs Apply the Install CV setting, can be set when you apply and then retry the Install CV the Install CV setting once. setting.
Table 33 Error Codes — Part Code 3010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3010 59118 Use this function only for zero formatted volumes. Do you want to continue this operation? Select [OK] to continue Write i to Control Blocks processing, or select [Cancel] to stop the processing. 5 3010 59333 The specified item will be canceled. Do you want to continue? Select [OK] to cancel the specified item and acquire progress.
Table 35 Error Codes — Part Code 3205 142 Part Code Error Number Error Message Recommended Action Severity Level 3205 2011 The status of the subsystem requires the maintenance (for example, the subsystem is blocked, the shared memory is inconsistent, or some other factor.) Call technical support. Check the status of the disk W storage system (if the storage system is blocked, inconsistency of shared memory, or some other factor.) If this problem persists, call technical support.
Table 35 Error Codes — Part Code 3205 (continued) Part Code Error Number Error Message Recommended Action Severity Level 3205 2200 The Concurrent Copy or the Hitachi Extended Remote Copy for Mainframe operation is in progress in the target volumes. Cancel the Concurrent Copy job or delete a Hitachi Extended Remote Copy for Mainframe pair via the host.
Table 35 Error Codes — Part Code 3205 (continued) Part Code Error Number Error Message Recommended Action Severity Level 3205 6534 The number of V-VOL groups that can be set to the subsystem exceeds the maximum. Decrease the number of E V-VOL groups registered to the storage system, and retry the operation. 5 3205 6535 You cannot make changes Release the logical path, and E because a logical path to the then change the volume still remains. configuration.
Table 35 Error Codes — Part Code 3205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3205 8957 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side. If this problem persists, call technical support. E 3 3205 8958 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side.
Table 35 Error Codes — Part Code 3205 (continued) 146 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3205 8970 An error occurred on the DKC side. If this problem persists, call technical support. An error occurred on the DKC side. If this problem persists, call technical support. E 3 3205 8971 Failed to update the configuration information. Call technical support. Reboot the SVP computer, E and retry the operation.
Table 36 Error Codes — Part Code 3210 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 3210 55001 The specified V-VOL group cannot be deleted. Check the specified content, and retry the operation. W 5 A V-VOL group cannot be deleted when it contains: • a path defined volume, • a LUSE volume. 3210 55101 The setting of V-VOL group is Check the settings, and retry W incorrect. the operation.
Table 37 Error Codes — Part Code 4005 Part Code Error Number Error Message 4005 5010 4005 Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5040 The number of requests Reduce the number of exceeds the maximum requests and retry the number that can be operation. processed. Reduce the number of requests and retry the operation.
Table 37 Error Codes — Part Code 4005 (continued) Part Code Error Number Error Message 4005 7310 4005 4005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 55243 The total of XP Cache LUN Check the settings, and then Software size of the CLPRs retry the operation. and the total of all XP Cache LUN Software size in the subsystem are not equal.
Table 37 Error Codes — Part Code 4005 (continued) 150 Part Code Error Number Error Message Recommended Action Severity Level 4005 55532 The specified extent is over the size which can be specified. Set the extent area within the E size which can be specified, and then retry the operation. 4005 55533 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 37 Error Codes — Part Code 4005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 4005 56542 The prestaging is not executed because the prestaging area does not exist. Check the XP Cache LUN Software setting. Set the prestaging area by using XP Cache LUN Software to use the prestaging function. W 6 4005 58511 The current XP Cache LUN Wait for a while, and then Software setting cannot be retry the operation.
Table 38 Error Codes — Part Code 4010 152 Part Code Error Number Error Message Recommended Action Severity Level 4010 1030 Part of the range is already in use. Correct the specified content, i and issue the request again. 0 4010 1032 The specified value is outside Correct the specified content, i the valid range. and issue the request again. 0 4010 2080 Prestaging not completed. Wait for a while, and press the Refresh button, and then change the same configuration again.
Table 39 Error Codes — Part Code 4105 Part Code Error Number Error Message Recommended Action Severity Level 4105 1603 This functionality is not available. XP Cache LUN Software is required. Install the necessary program E product. 6 4105 6012 An error occurred during server processing. If this problem persists, call technical support. An error occurred during SVP E processing. If this problem persists, call technical support. 3 4105 6023 An error occurred during server processing.
Table 39 Error Codes — Part Code 4105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 4105 56526 The resources of other SLPR(s) Correct the settings, and then E cannot be accessed. retry the operation. 6 4105 57007 The sum of the maximum Check the settings, and retry E values of the PCR capacity the operation. per CLPR does not match the maximum value of total PCR capacity.
Table 41 Error Codes — Part Code 5105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 5105 2015 A connection error has occurred. Retry the same operation. If E the same error occurs despite retrying, call technical support. 6 5105 2033 The SVP is now updating the statistics data. Wait for a while, and then select the [Refresh] button. The SVP is now gathering the W latest data. Internal processing in progress.
Table 41 Error Codes — Part Code 5105 (continued) Part Code Error Number Error Message 5105 7428 5105 Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 8002 The subsystem status is invalid. Call technical support. E 2 5105 8916 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 42 Error Codes — Part Code 5110 Part Code Error Number Error Message Recommended Action Severity Level 5110 59030 The monitoring data saved at To continue processing, select i present will be deleted. [OK]. Otherwise, select [Cancel]. Failure Level 5 The monitoring data currently saved will be deleted when you change the setting of the monitoring switch. If necessary, use the Export Tool to save the monitoring data.
Table 43 Error Codes — Part Code 5205 (continued) 158 Part Code Error Number Error Message Recommended Action Severity Level 5205 1084 No reserved volume can be allocated. Set Reserve volume, and retry E the operation. 6 5205 1085 The volume(s) are already used by XP Auto LUN. Retry the same operation. If nothing changes, call technical support. E 6 5205 1086 The RAID level of the target volume is not supported. Check the micro program version, and call technical support.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5205 1208 XP Auto LUN does not support the volume(s.) Retry the same operation. If nothing changes, call technical support. E 6 5205 1209 XP Auto LUN does not support the volume(s.) Retry the same operation. If nothing changes, call technical support. E 6 5205 1210 The number of target volumes Retry the same operation.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5205 1224 The volume(s) are already used by XP Auto LUN. Retry the same operation. If nothing changes, call technical support. E 6 5205 1225 The selected source volume and destination volume are the same volume. Retry the same operation. If nothing changes, call technical support.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message 5205 1238 5205 Recommended Action Severity Level Failure Level The specified volume(s) are Check the status of the already used by XP Business selected volume. Copy, Hitachi ShadowImage for z/OS, or XP FlashCopy Mirror. E 6 1239 The volume(s) is already being used by Data Migration. E 6 5205 1240 The specified volume(s) are Check the status of the already used by XP Business selected volume.
Table 43 Error Codes — Part Code 5205 (continued) 162 Part Code Error Number Error Message 5205 1254 5205 Recommended Action Severity Level Failure Level The specified volume cannot Select another volume. be used because the volume is being used by XP Flex Copy. E 6 1255 The specified volume cannot Select another volume. be used because the volume is being used by XP Flex Copy. E 6 5205 1606 The optional product (XP Auto Install the necessary program E LUN) is not installed. product.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message 5205 5013 5205 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5099 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message 5205 6502 5205 Recommended Action Severity Level Failure Level Processing in progress. Wait Retry the same operation for a while, and then retry the several times. If the same operation. error occurs, call technical support. i 0 6510 The subsystem is busy. Wait Retry the same operation for a while, and then retry the several times. If the same operation. error occurs, call technical support.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5205 7408 There is not enough valid monitoring data in the specified term. Retry the same operation several times. If the same error occurs, call technical support. E 6 5205 7409 Failed to write to the plan file Retry the same operation (hihsmpln.ini.) several times. If the same error occurs, call technical support.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action 5205 7420 There is insufficient XP Auto Retry the same operation LUN data to create migration several times. If the same plans. Check the following: error occurs, call technical support. • The time setting for the Severity Level Failure Level E 6 sampling term • The monitoring term 5205 7421 Cannot make proper migration plan by this function.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message 5205 8671 5205 Recommended Action Severity Level Failure Level A pair cannot be created Try creating the pair again because the volumes differ in by using the volumes with the number of LBAs. same number of LBAs. i 0 55059 The specified source volume is an XP Continuous Access volume or a Hitachi TrueCopy for z/OS volume. The specified target volume is an external volume.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action Severity Level 5205 55252 The specified source volume Check the source volume E is an internal volume. The setting and the target volume specified target volume is an setting. external volume that belongs to an XP Flex Copy pair. Therefore, the specified volumes cannot be used for migration.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message 5205 55431 5205 Recommended Action Severity Level Failure Level The volume(s) are already Confirm the setting of the being used by XP FlashCopy specified volume. Mirror Version 2. E 6 55432 The volume(s) are already Confirm the setting of the being used by XP FlashCopy specified volume. Mirror Version 2.
Table 43 Error Codes — Part Code 5205 (continued) 170 Part Code Error Number Error Message 5205 55552 5205 Recommended Action Severity Level Failure Level The specified plan is set Confirm the setting of the across an internal volume specified volume. and an external volume, and the volume is used by XP Continuous Access Journal or Hitachi Universal Replicator for z/OS. E 6 55586 The specified volume cannot Check the setting of the be migrated because an specified volume.
Table 43 Error Codes — Part Code 5205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5205 56526 The resources of other SLPR(s) Correct the settings, and then E cannot be accessed. retry the operation. 6 5205 58451 The subsystem is in internal If the problem persists despite W process. Retry the operation. retrying, call technical support.
Table 45 Error Codes — Part Code 5305 172 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5305 1064 The specified WWN is already being used. Correct the specified contents, and request the setting of the configuration information again. E 6 5305 1258 This port is not properly equipped. Retry the same operation. If nothing changes, call technical support. E 6 5305 2002 An error occurred during SVP processing.
Table 45 Error Codes — Part Code 5305 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5305 5104 The specified Performance Control group is already registered. Check the specified content, and retry. W 6 5305 5105 The target port(s) does not equip the monitored WWN(s.) Check the specified content, and retry. W 6 5305 5106 The target WWN is already registered in the port. Check the specified content, and retry.
Table 45 Error Codes — Part Code 5305 (continued) Part Code Error Number Error Message Recommended Action 5305 6036 An error occurred during SVP If the same error occurs E processing. If this problem despite retrying, call technical persists, call technical support. support. 2 5305 6050 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5305 6051 An error occurred during processing.
Table 45 Error Codes — Part Code 5305 (continued) Part Code Error Number Error Message Recommended Action Severity Level 5305 56303 An error occurred during SVP The error may be caused by E processing. a temporary communication failure. Reboot the SVP or If this problem persists, call select [Refresh All] on the File technical support. menu of XP Remote Web Console and refresh the configuration information to recover from the error. Failure Level 2 If this problem persists, call technical support.
Table 45 Error Codes — Part Code 5305 (continued) Part Code Error Number Error Message 5305 58575 5305 58576 Recommended Action Severity Level Failure Level An error occurred while If this problem persists, call connecting to the subsystem. technical support. Wait for a while, and then retry the operation. E 6 A communication time-out If this problem persists, call error occurred in the technical support. subsystem. Wait for a while, and then retry the operation.
Table 47 Error Codes — Part Code 5310 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5310 5106 Target WWN is already registered in the port. Check the specified content, and retry. i 5 5310 5107 The specified name is already Check the specified content, used. and retry. i 5 5310 5108 The specified name is already Check the specified content, used. and retry.
Table 47 Error Codes — Part Code 5310 (continued) 178 Part Code Error Number Error Message Recommended Action 5310 9077 Are you sure you want to delete the WWN? To continue processing, select i [OK]. To stop processing, select [Cancel]. 5 5310 9078 Are you sure you want to delete the Performance Control group? To continue processing, select i [OK]. To stop processing, select [Cancel]. 5 5310 9079 The Performance Control To continue processing, select i group is deleted because no [OK].
Table 47 Error Codes — Part Code 5310 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 5310 9335 Do you want to change the Select Yes to change the control status to No Control? control status. i 5 5310 59000 The Performance Control To continue processing, select i group extends across multiple [OK]. To stop processing, SLPRs. Do you want to select [Cancel].
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8104 It takes time for the change processing of pair status. Wait for a while, and then refresh the screen and confirm the pair status has been changed properly. If the pair status is not changed, check the MCU/RCU configuration and the condition of the paths between the CUs. It takes time for the change i processing of pair status.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8707 Parameter specified by Data Migration operation is invalid. A parameter specified by the i data migration operation is invalid. (For example, the R-VOL that is specified may already be in use as the R-VOL of another pair.) Check the status of the volumes and retry the operation. 4 6005 8708 The pair status of the R-VOL is not valid.
Table 48 Error Codes — Part Code 6005 (continued) 182 Part Code Error Number Error Message Recommended Action Severity Level 6005 8716 Specified port is not RCP. Check the configuration of E the LCP/RCP, and then either specify the correct port or change the port to RCP. 4 6005 8717 Invalid Destination Link Address. The specified logical address E must be either 00 or 01. Check the logical address and retry the operation. 4 6005 8718 The specified logical path already exists.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8727 The number of minimum Add the normal path(s), and i paths exceeds the number of then set the minimum number normal paths. of paths. 4 6005 8728 The number of minimum Take either of the following i paths exceeds the number of actions: normal paths. 1. Add normal paths, and then delete the paths. 2. Decrease the number of minimum paths, and then delete the paths.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8739 NVS status of MCU is not active. The MCU NVS status i specified by the host is not active. Set the NVS to on for the MCU, using any attached host, and then retry the operation. 4 6005 8740 NVS status of RCU is not active. The RCU NVS status specified i by the host is not active. Use any attached host to set the NVS to on for the MCU, and then retry the operation.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action 6005 8745 A volume cannot be used as Select another volume. an R-VOL when: Severity Level Failure Level i 4 • it is used by Hitachi Extended Remote Copy for Mainframe. • it is used by PPRC or XP Continuous Access. • it is used by Concurrent Copy. • it is in a reserved condition. • it is used by XP Continuous Access Journal or Hitachi Universal Replicator for z/OS.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action 6005 8752 Data Migration is not supported under the RCU Controller type. The RCU controller emulation i type does not support data migration. Call technical support. 4 6005 8753 An internal error occurred. Call technical support. E 4 6005 8754 Invalid MCU serial number or MCU SSID. Check the serial number or E SSID of MCU, and then retry with correct parameter.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8764 The specified R-VOL is not usable, or the device emulation type of the R-VOL is not supported by XP Continuous Access via serial interface. Confirm the status of the W specified R-VOL. See the OPENPLATFORM SECTION in the maintenance manual to confirm whether the device emulation type of the R-VOL is supported by XP Continuous Access via serial interface.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action 6005 8772 Change pair operation failed The pair option change E due to communication error operation failed, either or the R-VOL status is invalid. because a communication error occurred or because the R-VOL status is not valid. Verify the status. Also view the License Key window at the RCU side and check the licensed capacity for Volume Retention Manager.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8781 Hitachi TrueCopy for z/OS The option must be installed i function is not installed in the in the MCU and RCU before specified controller. a volume pair can be created. 4 6005 8782 Data Migration function is not The data migration option i installed in specified must be installed in the controller.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8793 The XP Continuous Access Install XP Continuous Access i function is not installed in the in the MCU and the RCU, specified controller(s.) and then retry the operation. 4 6005 8794 The XP Continuous Access Install XP Continuous Access i function is not installed in the in the MCU and the RCU, specified controller(s.) and then retry the operation.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8803 Too many RCUs in this CT Group. The add pair operation failed i because there are too many RCUs in this CT group. If the timer type is None, and then 4 RCU have already been added. If the timer type is Local or System, and then 1 RCU has already been added. Check configuration of CT group numbers already used on both MCU and RCU. Register a new CT group.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8809 Wait. Retry Add Pair (Paircreate)/Resume Pair (Pairresync) operation in a few minutes. Add/resume pair operation failed. The specified volume or another volume in the same group being changed to simplex/suspend status in RCU.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8817 Preset Suspension is effective Cancel the preset suspension i in the CT Group. in the CT group, and then retry the operation. 4 6005 8818 Preset Suspension is effective Cancel the preset suspension i in the CT Group. in the CT group, and then retry the operation. 4 6005 8819 A volume cannot be used as Select another volume.
Table 48 Error Codes — Part Code 6005 (continued) 194 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8826 An internal error occurred. Call technical support. E 4 6005 8827 Wait a few minutes and retry the Add Pair (Paircreate)/Resume Pair (Pairresync.) Retry the operation in a few minutes.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8837 An internal error occurred. Call technical support. E 4 6005 8838 Specified volume is not part The specified volume is not of a Continuous Access pair. part of a Continuous Access pair. Check the volume. i 4 6005 8839 Invalid RCU serial number, SSID, Link Address or Controller ID.
Table 48 Error Codes — Part Code 6005 (continued) 196 Part Code Error Number Error Message 6005 8848 6005 Recommended Action Severity Level Failure Level Wait a few minutes and retry The suspend pair (Pairsplit-r) the Suspend Pair (Pairsplit-r) operation failed. A few operation. minutes later, refresh the screen, confirm if the specified volumes are in the permissible status, and then retry the operation.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8855 Delete (Pairsplit-S) operation failed because specified volume or other volume in the same group is in status transition. The operation failed, because i of one of the following reasons: 1. The status of the specified volume or another volume in the same group is Deleting. 2. The status of the specified volume or another volume in the same group is Suspending.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message 6005 8862 6005 Recommended Action Severity Level Failure Level Wait a few minutes and retry The delete pair (Pairsplit-S) the Delete Pair (Pairsplit-S) operation failed. A few operation. minutes later, refresh the screen, confirm if the specified volumes are in the permissible status, and then retry the operation. i 4 8863 Unknown Error Code. The XP Remote Control computer detected an unknown error code.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8877 An internal error occurred. Call technical support. E 4 6005 8878 CT Group is not active. Verify that the CT group is active in the MCU. E 4 6005 8879 At least one asynchronous pair is active in this group. Verify that there are no active i asynchronous pairs in this group, and retry the operation. 4 6005 8880 Wait.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 8898 Pending data exists on the port. Add another path, or delete all pairs on the RCU. Then retry the operation. i 4 6005 8899 An internal error occurred. Call technical support. E 4 6005 8900 An error occurred during the Call technical support. port change. E 4 6005 8901 An error occurred during the Call technical support. port change.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8907 The extended SM is not equipped in RCU. Install the extended shared E memory to RCU according to the installation instruction of the extended shared memory for XP Continuous Access (Shared Memory Size Configuration dialog box.) 5 6005 8908 Invalid parameter. Check the value of the specified parameter and retry. i 4 6005 8909 A Port exchange error occurred.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8922 The specified MCU does not Confirm whether the MCU E support serial XP Continuous supports serial XP Continuous Access connections. Access connections. Install the microcode of version that supports serial XP Continuous Access connections, or use fibre XP Continuous Access connections.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8936 The Paircreate operation failed. The version of the specified RCU does not support Continuous Access with the NAS volume. Check the microcode version W of the RCU. 4 6005 8937 The Paircreate operation with the Fibre Channel XP Continuous Access connection failed because there are pairs with the serial XP Continuous Access connection in the specified MCU.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 8947 The external volume that is mapped to an internal volume is connected to the port. Release the setting of the i external volume, and retry the operation. 6005 8948 The specified port is receiving Stop I/O operations, and I/O requests. retry. i 4 6005 8949 An internal error occurred. Call technical support. E 4 6005 8950 An internal error occurred.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message 6005 8986 6005 Recommended Action Severity Level Failure Level Cannot create a pair, Verify that both MCU and because the serial interface RCU support the serial is not supported by either the interface. MCU or the RCU. i 4 8987 Cannot create a pair, because LUSE volumes consisting of volumes from different CUs are not supported by either the MCU or the RCU.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6005 58322 The pair cannot be created because the specified R-VOL is a LUSE volume that is set across the multiple CLPRs. Select another volume, and retry the operation. i 5 6005 58357 A pair cannot be created, because you tried to create a volume pair formed with a volume to which VMA is set by XP LUN Security Extension Softwareand a volume without VMA.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 58460 The specified M-VOL is already used as a primary data volume for XP Continuous Access Journal or Hitachi Universal Replicator for z/OS. To use the M-VOL in conjunction with one of these program products, recreate the XP Continuous Access Journal pair or the Hitachi Universal Replicator for z/OS pair using a mirror ID other than 0, and retry the operation.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 58568 A pair cannot be created because the specified M-VOL is being shredded by XP LUN Security Extension Software. Retry the operation after the shredding is completed. Confirm that the shredding i has completed in the XP LUN Security Extension Software window, and then retry the operation.
Table 48 Error Codes — Part Code 6005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6005 58713 The licensed capacity of XP Continuous Access Asynchronous Software or TrueCopy Asynchronous for Mainframe on the RCU is insufficient. Check the licensed capacity W of this program product and the related program products. Failure Level 5 See the user's guides of Continuous Access or Hitachi TrueCopy for z/OS for details on the licensed capacities.
Table 49 Error Codes — Part Code 6007 Part Code Error Number Error Message 6007 5074 6007 Recommended Action Severity Level Failure Level Continuous Access or Hitachi Install Continuous Access or TrueCopy for z/OS is not Hitachi TrueCopy for z/OS. installed. i 4 6000 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 6007 6002 An error occurred during SVP If this problem persists, call processing.
Table 50 Error Codes — Part Code 6010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 5015 The R-VOL Write value is invalid. Specify the correct value. Correct the specified contents, and retry. W 5 6010 5016 The Split-r/Suspend kind value is invalid. Specify the correct value. Correct the specified contents, and retry. W 5 6010 5017 The Update value is invalid. Specify the correct value. Correct the specified contents, and retry.
Table 50 Error Codes — Part Code 6010 (continued) 212 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 5144 Some of the entered values are incorrect. Check the values and then specify correct values. Check the entered values, and then specify correct values. W 0 6010 7060 A client processing error occurred. Call technical support. E 2 6010 7301 A client processing error occurred. Call technical support.
Table 50 Error Codes — Part Code 6010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 9024 Are you sure you want to The same as the message. exchange the specified ports? Confirm the associated channel paths are offline. W 5 6010 9025 Are you sure you want to To continue the operation, W switch the ports? If the XP select [OK]. Otherwise, select Continuous Access paths exist [Cancel]. on the ports, delete them beforehand.
Table 50 Error Codes — Part Code 6010 (continued) 214 Part Code Error Number Error Message 6010 9105 6010 Recommended Action Severity Level Failure Level The value that is under setup To close the window, select is not reflected yet. Do you [OK]. To not close the want to exit? window, select [Cancel]. i 0 9106 The value that is under setup To change the mode, select is not reflected yet. Do you [OK]. To not change the want to change the mode? mode, select [Cancel].
Table 50 Error Codes — Part Code 6010 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6010 9122 Are you sure you want to output pair status to a snapshot file? To output pair status into a i snapshot file, select [OK]. To cancel this operation, select [Cancel]. 0 6010 9124 This process may take up to %d minutes. Do you want to continue? To continue the operation, select [OK]. To cancel the operation, select [Cancel].
Table 50 Error Codes — Part Code 6010 (continued) 216 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 9304 WARNING: Group or C/T The same as the message is specified for Delete Range. Confirm all pairs in the group are synchronized. If some volumes are not synchronized, full volume initializations are required before re-using them. W 0 6010 9305 There are no initiator ports. Set the port to Initiator before W registering RCU.
Table 50 Error Codes — Part Code 6010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 9322 Snapshot has failed. Select [OK]. Then contact maintenance staff. E 4 6010 9323 Snapshot has been canceled. Select [OK]. i 0 6010 9324 The specified operation is prohibited while the script is running. Try again after the script ends. W 0 6010 9325 The script is terminated forcibly. Select [OK].
Table 50 Error Codes — Part Code 6010 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6010 59001 Are you sure you want to cancel the change operation of the option parameter that you specified? To cancel the change operation of the option parameter, select OK. If you don't want to cancel the change operation, select Cancel. W 5 6010 59011 Are you sure you want to download the %s file? To download the file, select i [Yes].
Table 51 Error Codes — Part Code 6105 Part Code Error Number Error Message Recommended Action 6105 56524 This function cannot be used Select another window. To by the storage partition set this function, contact the administrator. storage administrator.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action 6505 7310 This error code is not registered. If the same error occurs E despite retrying, call technical support. 6505 8000 An error occurred during SVP Retry the operation. If this processing. If this problem problem persists, call persists, call technical technical support. support.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8708 The pair status of the secondary data volume is incorrect. Refresh the window, and then i check the pair status. If possible, retry the operation on the secondary data volume. 4 6505 8709 Continuous Access operation Replace the channel adapter, E was rejected. and then retry the operation.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8722 Path creation failed. Check the path connections between the local and the remote storage systems, and then retry the operation. E 4 6505 8723 The Edit Path operation was rejected because the specified path is the last path of some Continuous Access pairs. Add another path, or delete all pairs on the remote storage system.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8733 XP Continuous Access Journal or Hitachi Universal Replicator for z/OS is not installed in the subsystem. XP Continuous Access Journal i or Hitachi Universal Replicator for z/OS must be installed in the storage system when you create a path or a pair for XP Continuous Access Journal or Hitachi Universal Replicator for z/OS.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8744 The specified primary data volume cannot be used. Check whether the primary data volume is in any of the following conditions: W 4 • Data in the primary data volume is being copied; correction copy or drive copy is in progress. • The primary data volume is in correction access condition. • The primary data volume is blocked.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 8753 An internal error occurred. Check the SSB log, and then E call technical support. 6505 8757 One side of the cache or the Check the status of the cache W shared memory is blocked in and the shared memory in the the primary subsystem. primary storage system. Ensure that the cache and shared memory is not blocked.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 8795 The operation failed because Check the status of the i the specified primary data primary data volume from the volume was used by XP host or the SVP. Business Copy or Hitachi ShadowImage for z/OS and satisfied one of the following conditions: Failure Level 4 • The volume was an XP Business Copy S-VOL in non-PSUS status.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action 6505 8819 The specified secondary data Check the status of the volume must not be: secondary data volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8835 The Add Pair (Paircreate) operation failed because you tried to create volume pairs which exceeded the licensed capacity of the secondary subsystem. See the license key at the secondary storage system and check the licensed capacity of volumes. To create more pairs, purchase a license key for larger capacity. W 0 6505 8887 An internal error occurred.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8922 The primary subsystem does not support XP Continuous Access via serial interface. Check whether the primary storage system supports XP Continuous Access via serial interface. Install the microcode that supports XP Continuous Access via serial interface, or execute XP Continuous Access via fibre interface.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 8949 An internal error occurred. Check the SSB log, and then E call technical support. 4 6505 8950 An internal error occurred. Check the SSB log, and then E call technical support. 4 6505 8977 The Add Pair (Paircreate) Check the status of the operation failed because the specified secondary data specified secondary data volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58016 The cache is or the shared memory is in an abnormal state. Call technical support. i 0 6505 58017 The specified volume is being Check the status of the connected by a mainframe specified volume from the host. mainframe host. i 0 6505 58018 The specified volume is a reserve volume of a mainframe host.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58030 The threshold for starting creation of synchronous journal must be larger than the threshold for starting creation of asynchronous journal. Ensure that the threshold for i starting creation of synchronous journal is larger than the threshold for starting creation of asynchronous journal.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58068 Invalid parameter (Journal Control.) Check the specified JNL Control parameter. i 0 6505 58069 Invalid parameter (Suspend Condition-Journal Full.) Check the specified Suspend i Condition parameter. 0 6505 58070 Invalid parameter (Suspend Condition-Master Journal Failure.) Check the specified Suspend i Condition parameter.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message 6505 58084 6505 Recommended Action Severity Level Failure Level The specified primary data Check the status of the volumes cannot be paired specified primary data with another volume, because volume. the primary data volume is used as a journal volume. i 0 58085 The specified primary data Check data volumes in the volume is not registered in the specified primary journal specified journal group. group.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58096 The specified volume is a reserve volume of a mainframe host. Check the status of the specified volume from the mainframe host. i 0 6505 58097 XP Continuous Access Journal or Hitachi Universal Replicator for z/OS is not installed in the primary subsystem.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58105 XP Continuous Access Journal or Hitachi Universal Replicator for z/OS is not installed in the remote subsystem. XP Continuous Access Journal i or Hitachi Universal Replicator for z/OS must be installed in both the local and remote storage systems when you create paths or pairs with XP Continuous Access Journal or Hitachi Universal Replicator for z/OS.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message 6505 58271 The specified secondary data volume cannot be used because of the following reasons: Recommended Action Severity Level Check the following items on i the XP LUN Security Extension Software window if the specified secondary data • S-VOL Disable is set by XP volume is an open-system volume. LUN Security Extension Software.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58279 The emulation type of the specified secondary data volume and the restore journal volume is incorrect due to one of the following reasons: Check the emulation type of i the specified secondary data volume or the restore journal volume. Failure Level 0 • The emulation type is not supported. • The combination of emulation types within the journal group is incorrect.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message 6505 58288 6505 Recommended Action Severity Level Failure Level The specified primary data Check the status of the volume is already paired with specified primary data another volume. volume. i 0 58289 The specified secondary data Check the status of the volume is already paired with specified secondary data another volume. volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58297 The specified primary data volume is being used by Hitachi Extended Remote Copy for Mainframe or another program product.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58323 The Add Pair (Paircreate) Specify another primary data W operation failed because the volume, and retry the specified primary data operation. volume was being used by XP Continuous Access Asynchronous Software or TrueCopy Asynchronous for Mainframe.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message 6505 58333 6505 Recommended Action Severity Level Failure Level Because the specified journal Check the attribute of the group is a restore journal specified journal group. group, the parameter related to the inflow cannot be changed. i 0 58334 Because the status of the specified journal group is neither Initial nor Stop, the parameter related to the inflow cannot be changed.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58344 The Add Pair (Paircreate) Check the specified operation failed because the secondary data volume and specified secondary data specify a non-LUSE volume. volume is a LUSE volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message 6505 58353 The operation failed because the specified secondary data volume was one of the following: Recommended Action Severity Level Failure Level W 0 Check whether the specified W primary data volume is used by any of the following program products: 0 Check the status of the specified secondary data volume in the XP Business Copy window, Continuous Access window, Hitachi • An XP Business Copy ShadowImage
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58455 The Add Pair operation or the Resume Pair operation failed because the specified primary data volume was a T-VOL of XP FlashCopy Mirror. From the XP FlashCopy W Mirror window, check the status of the specified primary data volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action 6505 58490 Only the pair option of the primary data volume was updated. Failed to update the pair option of the secondary data volume. A communication error W between the primary and the secondary storage systems occurred, or the microcode of the secondary storage system does not support the change pair option function.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58506 The specified volume is already being used by Data Migration. Release the Data Migration setting. W 5 6505 58507 The Add Pair operation failed Release the Data Migration because the specified setting. primary data volume was used by Data Migration.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58551 The Add Pair (Paircreate) operation failed because the specified primary data volume is a NAS user volume and it is used as a P-VOL for Continuous Access. Confirm that the specified W primary volume is a NAS user volume and it is used as a P-VOL for Continuous Access.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58565 The Add Pair (Paircreate) operation failed because the specified secondary data volume is being shredded by XP LUN Security Extension Software. Retry the operation after the shredding is completed. Confirm that the shredding W has completed in the XP LUN Security Extension Software window, and then retry the operation.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58596 The operation to change the status to the status ready for Delta resync cannot be created because At-Time Split was set to the specified restore journal group. Check whether At-Time Split W is set to the specified restore journal group by using Business Continuity Manager.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58607 Journal groups cannot be Check the journal groups in deleted from the extended the specified extended CT consistency group (EXCTG), group. because the specified journal group was not registered. W 0 6505 58608 The Resume Pair operation failed.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58617 Journal groups cannot be added to the extended consistency group (EXCTG), because the attributes of the EXCTG and the journal group are different. Check the attributes of the specified extended consistency group (EXCTG) and the journal group.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58641 The specified volume cannot be used as a journal volume because the volume is set by XP Cache LUN Software or Hitachi Flash Access z/OS . Confirm whether the specified W volume is set by XP Cache LUN Software or Hitachi Flash Access z/OS .
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58687 The status of the other mirror If the problem persists despite W of the Delta resync did not retrying, call technical change. support. 0 6505 58688 Delta resync failed because the specified primary data volume was not ready for Delta resync. Check the status of the specified primary data volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58694 The Delta resync operation failed. Check the status of the secondary data volume, or the status of the connected communication line. Check the status of the W secondary data volume, or the status of the connected communication line. When no abnormality is found in the status of the secondary data volume or the communication line, call technical support.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58700 The operation to change the status to the status ready for Delta resync failed. The specified secondary data volume should meet the following requirements. Check the status of the specified secondary data volume. W 0 Delta resync cannot be executed. Delete the pair ready for Delta resync and copy all data in the primary data volume.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6505 58707 The Add Pair (Paircreate) Check the status of the operation or the Resume Pair specified secondary data (Pairresync) operation failed volume. because the status of the specified secondary data volume was Not Ready.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58718 The licensed capacity of XP Continuous Access Journal or Hitachi Universal Replicator for z/OS on the RCU is insufficient. Check the licensed capacity W of this program product and the related program products. Failure Level 5 For license capacities, see the Continuous Access or Hitachi TrueCopy for z/OS user guides.
Table 52 Error Codes — Part Code 6505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6505 58720 The licensed capacity of XP Continuous Access Asynchronous Software or TrueCopy Asynchronous for Mainframe on the MCU is insufficient. Check the licensed capacity W of this program product and the related program products. Failure Level 5 For license capacities, see the Continuous Access or Hitachi TrueCopy for z/OS user guides.
Table 53 Error Codes — Part Code 6507 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6507 5036 Two or more commands which were not able to be processed were demanded. Check the settings, and retry E the operation. 5 6507 6012 An error occurred during SVP If the problem persists despite E processing. If this problem retrying, call technical persists, call technical support. support.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 7301 An error occurred in client logic. Call technical support. E 2 6510 7302 An error occurred in client logic. Call technical support. E 2 6510 7303 An error occurred in client logic. Call technical support. E 2 6510 7440 An error occurred during processing. If this problem persists, call technical support.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 9104 Do you want to change the mode? To switch the mode, select OK. If not, select [Cancel. i 0 6510 9105 The value that is under setup To discard the current settings i is not reflected yet. Do you and exit the window, select want to exit? OK. If not, select Cancel.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 9128 The specified volume was not Select [OK], and then specify i found. the correct volume. 0 6510 9155 The history file has been updated. Select the OK button to display the history logs from the beginning. Select the OK button. i 0 6510 9303 There are no valid volumes. Check the device emulation or the definition of the SCSI path.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 55202 The specified controller ID cannot be used. Check the specified controller W ID. 0 6510 55207 Some of the specified values are incorrect. Two times the value of M-JNL Cache plus the value of R-JNL Cache must be equal to or less than 100.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message 6510 59006 No more journal volumes can Check the number of journal i be registered, or too many volumes in the specified volumes are selected. journal group, or check the number of the selected volumes. 0 6510 59007 Are you sure you want to delete the specified subsystems? To delete the specified storage system, select OK. If not, select Cancel.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 59039 You cannot add journal Purchase a license for XP volumes because XP Continuous Access Journal, Continuous Access Journal is and then install it. not installed. W 0 6510 59042 There are no valid journal groups. All journal groups are used W by Hitachi Universal Replicator for z/OS or XP Continuous Access Journal.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 59112 The CLPR number of the specified data volume is different from the CLPR number of the data volume in the Preset list. In this operation, specify only one CLPR number. Specify only the volume that has the same CLPR number as the CLPR number of the volume in the Preset list.
Table 54 Error Codes — Part Code 6510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6510 59327 You cannot specify [Entire] or Check the status of the [None] to the Initial copy specified master journal mode under the current status group. of the specified master journal group. Check the status of the specified master journal group.
Table 56 Error Codes — Part Code 6610 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6610 5030 The displayed information has not been changed. Specify the data that you want to register in the SVP. Then retry the operation. W 0 6610 5137 The Operation value is invalid. Specify the correct value. Check the contents, and retry. W 0 6610 5138 The value specified for Check the contents, and retry. W Gathering Interval is invalid.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6610 9025 Are you sure you want to Remove XP Continuous W switch the ports? If the XP Access paths associated with Continuous Access paths exist the ports. on the ports, delete them beforehand. 5 6610 9026 Are you sure you want to switch the ports? To continue to change ports, W select [OK].
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6610 9115 The monitoring was stopped by another operator. The graph will be closed. Select [OK]. i 0 6610 9116 Another operator has Select [OK]. changed the Gathering Interval value. The graph will be closed. i 0 6610 9117 Are you sure you want to close the graph? To close the graph, select [OK]. Otherwise, select [Cancel].
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6610 9308 You set the same path more than once. The duplicate paths are excluded. Since there are duplicated W paths in the added paths, the duplicated paths will be eliminated. Select [OK] to continue. 0 6610 9309 All paths which you set have already been registered. This operation will terminate because there is no path which can be added.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6610 55229 You want to forcibly delete pairs, but there are some pairs where Group is not specified as the range. Specify normal deletion, or specify Group as the range. W 0 W 5 Specify Group as the range when you want to forcibly delete pairs. 6610 55644 To delete pairs, click Yes. If WARNING! There are not, click No.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action 6610 59009 Since the number of preset data exceeded the maximum, the excess data were discarded. No more preset data can be stored. Select [OK]. Apply the preset i data to the disk storage system, and then retry the operation. 0 6610 59010 WARNING: Check the contents of the primary and secondary volumes. If the contents match, select [Yes]. Otherwise, select [No].
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6610 59041 Warning: A mainframe volume is included in the journal volumes to be deleted. To delete the journal volume, W select [Yes]. If you do not want to delete the journal volume, select [No]. Note the following points if you have made volume pairs by using this journal group before. It is recommended that you record the CU number and the LDEV number of the mainframe volume.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action 6610 59108 The master journal group Check the master journal number for the specified data group number for the volume exceeds 0x0F. specified data volume. Severity Level Failure Level W 5 Change the journal group number if you are performing an Add Pair (Paircreate) operation. Delete the data volume from the Preset list if you are performing a Resume Pair (Pairresync) operation.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6610 59151 The current microcode version of DKCMAIN only supports OPEN-V as the emulation type of a journal volume. To use a mainframe volume W as a journal volume, call technical support and update the microcode version of DKCMAIN. 6610 59152 There are two or more kinds Check the emulation type of of emulation types that the specified volume.
Table 56 Error Codes — Part Code 6610 (continued) Part Code Error Number Error Message Recommended Action 6610 59328 The journal volume cannot be deleted because the attribute of the mirror for the journal group is master and the status of the mirror is Hold. Change the status of the W mirror of the journal group to Initial, and then retry the operation. 0 6610 59329 The serial number of the local DKC is entered.
Table 57 Error Codes — Part Code 6805 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6805 7310 This error code is not registered. If the same error occurs W despite retrying, call technical support. 0 6805 8001 A communication time-out error occurred in the subsystem. Wait for a while, and then retry the operation. Retry the operation. If the E same problem persists despite retrying, call technical support.
Table 57 Error Codes — Part Code 6805 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 6805 55216 The Level 2 Suspend setting is incorrect. Correct the setting, and then retry. If the same problem persists despite retrying, call technical support. W 5 6805 55217 The maximum number of SLPRs that can be set was exceeded. Specify the number of SLPRs within the valid range. W 5 6805 55218 The Level 1 Sleep setting is incorrect.
Table 58 Error Codes — Part Code 6810 (continued) Part Code Error Number Error Message Recommended Action Severity Level 6810 9111 Do you want to delete the To delete the specified line of W specified line of settings from settings from the Preset list, the Preset list? select [OK]. Otherwise, select [Cancel]. 0 6810 55212 The options Block Option and Do not Block (Volume Level) cannot be specified at the same time. Correct the setting, and then retry.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 5626 The specified volume cannot be used because it is write-protected by XP LUN Security Extension Software. Select the OK button. i 0 7005 5654 This operation has been rejected, The specified volume(s) are being used by XP Flex Copy. Specify other volume(s), or release the XP Flex Copy setting.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8500 The program product is not installed. Check if the necessary key for the program product is installed. i 0 7005 8501 The command was rejected, because a status transition was in progress. Wait for a while, and retry the operation. i 0 7005 8502 You cannot reserve the Delete the Continuous Access i volume, because a pair.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action 7005 8512 Cannot perform Pairresync or Detach the S-VOL from the i Pairsplit-E operation because host, or delete the Continuous of the path group setting. Access path. 0 7005 8513 The command was rejected. The specified P-VOL is being used from the host or by Continuous Access.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8528 An internal logic error occurred. Call technical support. i 0 7005 8529 An internal logic error occurred. Call technical support. i 0 7005 8530 An internal logic error occurred. Call technical support. i 0 7005 8531 An internal logic error occurred. Call technical support.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8549 The P-VOL is not implemented. You cannot execute the operation for the volume which is not implemented. i 0 7005 8550 The P-VOL cannot be used. Call technical support, and check if the volume status is normal. i 0 7005 8551 The P-VOL is being formatted. Wait until the volume is formatted, and retry the operation.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7005 8567 The number of effective lists is invalid. Check the contents, and retry. i 7005 8568 The emulation type is invalid. Specify the volume of the supported emulation type. i 0 7005 8569 The number of multiple jobs exceeded the maximum. i 0 7005 8570 The selected volume does not Refresh the screen, and retry exist. the operation.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7005 8586 The number of groups that can be set in the same subsystem is invalid. Check the contents, and retry. i 0 7005 8587 The number of pairs that can Check the contents, and retry. i be set in the same group is invalid. 0 7005 8588 The specified group number is not set. Check the contents, and retry. i 0 7005 8589 The specified group name is invalid.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8605 The Pairresync command was Check the pair status. issued to a device in the SMPL status. i 0 7005 8606 Cannot create a new pair with this volume, because it is shared as a Continuous Access pair volume. Delete the Continuous Access i pair, and then retry the operation.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8626 The SMPL command was rejected, because the high-speed Split was in progress. After the high-speed Split is completed, retry the operation. i 0 7005 8627 The Reverse Resync command After the high-speed Split is was rejected, because the completed, retry the high-speed Split was in operation. progress.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8641 The L1 pairs contain a pair in the Reverse Copy status. You cannot execute the specified operation. Release the Reverse Copy for the operation. i 0 7005 8642 The L2 pairs contain a pair in the Reverse Copy status. You cannot execute the specified operation. Release the Reverse Copy for the operation.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 8655 An invalid secondary SSID is Check the contents, and retry. i specified for the Paircreate or Pairresync command. 0 7005 8656 The secondary SSID specified Check the contents, and retry. i for the pairsplit-S or pairsplit command is invalid. 0 7005 8657 The Swap&Freeze option Check the setting you cannot be specified, because specified in Option tab.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message 7005 56524 7005 Recommended Action Severity Level Failure Level This function cannot be used Select another window. To by the storage partition set this function, contact the administrator. storage administrator. E 3 57101 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7005 58261 The Reverse Copy or Quick Change the status of the i Restore command has been Continuous Access pair, and rejected, because the P-VOL then retry the operation. is used as the S-VOL of a Continuous Access pair whose status is not Suspend. 0 7005 58262 A pair cannot be created because shared memory for differential tables is insufficient.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 58479 The operation cannot be performed, because the specified S-VOL is a P-VOL for XP Snapshot. Release the XP Snapshot pair W or select another volume. 5 7005 58480 The operation cannot be performed, because the specified S-VOL is a virtual volume. Specify another volume.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 58572 An error occurred while If this problem persists, call connecting to the subsystem. technical support. Wait for a while, and then retry the operation. E 6 7005 58573 This function is not supported. Check the DKCMAIN E microcode version and the SVP microcode version, because these versions might be mismatched.
Table 59 Error Codes — Part Code 7005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7005 58632 The reserve volume setting failed because the specified volume was used by Delta resync of XP Continuous Access Journal. Check the volume, and then retry the operation. W 5 7005 58711 The operation failed because Refresh the XP Business Copy W the specified MU number was window, and check the MU already used. Specify other number that can be used.
Table 61 Error Codes — Part Code 7010 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7010 5124 You cannot select more than one operation at a time. Multiple volumes cannot be W processed in the operation. Process one volume at a time. 7010 5125 No target volume is selected. Select the target volume. 7010 5126 7010 Failure Level 0 W 0 You cannot create another L2 pair, because the number of L2 pairs exceeds the maximum.
Table 61 Error Codes — Part Code 7010 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7010 9005 An error occurred. Check the An error occurred during the i error code. indicated operation. See the error code for each operation in Preset Volume list. 0 7010 9101 Do you want to cancel? To cancel, press the OK button. i 0 7010 9102 Do you want to apply? Select [OK] to execute the operation.
Table 62 Error Codes — Part Code 7105 Part Code Error Number Error Message 7105 5099 7105 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5625 You cannot create another pair, because the number of pairs in the group exceeds the maximum. Select the OK button.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7105 8504 The command was rejected. The operation failed, because i of one of the following reasons: 1. You cannot execute the operation on the specified pair / volume. 2. The pairs of the Normal volume and CV cannot execute QuickRestore. 3. You cannot execute the operation on the intermediate volume. 4.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action 7105 8515 The number of cylinders in Check the contents, and retry. i the reserved volume exceeds the maximum. 0 7105 8516 The number of S-VOL cylinders exceeds the maximum. Check the contents, and retry. i 0 7105 8517 The number of T-VOL cylinders exceeds the maximum. Check the contents, and retry. i 0 7105 8518 You cannot create a pair, Check the emulation type.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7105 8533 The emulation type of the specified reserved volume is not supported. Specify the emulation type of i the supported volume. 0 7105 8535 A processor failure was detected. Call technical support. i 0 7105 8536 A cache failure was detected. Call technical support. i 0 7105 8537 The cache capacities do not match. Call technical support.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7105 8553 The T-VOL is not implemented. You cannot execute the operation for the volume which is not implemented. i 0 7105 8554 The T-VOL cannot be used. Call technical support, and check if the volume status is normal. i 0 7105 8555 The T-VOL is being formatted. Wait until the volume is formatted, and retry the operation.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7105 8573 The volume is defined as a source volume for XP Auto LUN. Check the corresponding condition. i 0 7105 8574 The volume is defined as a target volume for XP Auto LUN. Check the corresponding condition. i 0 7105 8575 The selected volume is not a reserved volume. Check the contents, and retry.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action 7105 8591 The specified pair is already Check the contents, and retry. i set in another group. 0 7105 8592 The command was rejected, Check the capacity of the because the licensed capacity installed license key. To was exceeded. create more pairs, purchase a license key for larger capacity. i 0 7105 8593 The S-VOL is a source volume Check the corresponding for XP Auto LUN. condition.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7105 8609 The specified volume is not set as a reserved volume. Check the contents, and retry. i 7105 8610 The T-VOL is a target volume Check the corresponding for XP Auto LUN. condition. 7105 8611 The specified volume is a T-VOL. 7105 Failure Level 0 i 0 Check the contents, and retry. i 0 8612 The specified volume is not a Check the contents, and retry. i T-VOL.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action 7105 8631 The specified CU number is invalid. Check the contents, and retry. i 0 7105 8632 The timing of issuing the command is invalid. Call technical support. i 0 7105 8633 The abnormal status is invalid. Call technical support.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 7105 8646 The Reverse Copy request Delete the Continuous Access i was rejected, because the pair. S-VOL was shared with a Continuous Access pair in the non-suspend status. 0 7105 8647 The Reverse Copy command Delete the Continuous Access i has been rejected, because pair. the T-VOL is shared with an M-VOL of a Continuous Access pair.
Table 62 Error Codes — Part Code 7105 (continued) 310 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7105 8697 The command has been rejected, because the specified T-VOL is being used as the volume of an XP FlashCopy Mirror Version 2 pair. Release the relationship to delete the XP FlashCopy Mirror Version 2 pair, or specify another volume.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7105 8996 The command has been rejected, because the subsystem is busy. Wait for a while, and retry the operation. W 0 7105 55645 Quick Restore cannot be Use the Reverse Resync executed because the option. specified pair is composed of the external volumes with different cache mode settings.
Table 62 Error Codes — Part Code 7105 (continued) 312 Part Code Error Number Error Message Recommended Action Severity Level 7105 58004 The command has been rejected because the issued request is an operation that cannot be performed with a volume that can be used from either the mainframe or open-system hosts. The requested operation i cannot be performed. Check the status of the specified volume.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7105 58356 The command was rejected, because the specified volume was used by Hitachi Universal Replicator for z/OS and Hitachi TrueCopy for z/OS. To continue the operation, i release the Hitachi Universal Replicator for z/OS pair or the Hitachi TrueCopy for z/OS pair, and retry the operation.
Table 62 Error Codes — Part Code 7105 (continued) Part Code Error Number Error Message 7105 58630 7105 7105 Recommended Action Severity Level Failure Level The operation failed because Check the volume and then the specified S-VOL was used retry the operation. by Delta resync of Hitachi Universal Replicator for z/OS. W 5 58631 The operation failed because Check the volume and then the specified T-VOL was used retry the operation. by Delta resync of Hitachi Universal Replicator for z/OS.
Table 63 Error Codes — Part Code 7110 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 7110 7311 The settings could not be applied. Wait for a while, and retry W the operation. If the same error occurs despite retrying, call technical support. 0 7110 7312 The password could not be acquired. Call technical support. W 0 7110 7313 Error details not available. Call technical support. W 0 7110 7440 An error occurred during processing.
Table 63 Error Codes — Part Code 7110 (continued) Part Code Error Number Error Message Recommended Action 7110 9378 Do you want to disable the To continue processing, select i setting to expand the number [OK]. To stop processing, of relationships? select [Cancel]. 0 7110 55003 The selected T-VOLs include a volume or volumes that is/are paired. i 0 7110 55004 The number of selected Correct the number of i S-VOLs doesn't match the selected S-VOLs and T-VOLs. number of selected T-VOLs.
Table 64 Error Codes — Part Code 8005 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8005 2145 A connection error has occurred. Retry the same operation. If E the same error occurs despite retrying, call technical support. 8005 3003 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 8005 5010 An error occurred during SVP If this problem persists, call processing.
Table 64 Error Codes — Part Code 8005 (continued) Part Code Error Number Error Message 8005 7111 8005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 8001 An error occurred while connecting to the subsystem. Wait for a while, and then retry the operation. Retry the same operation several times. If the same error occurs, call technical support.
Table 64 Error Codes — Part Code 8005 (continued) Part Code Error Number Error Message Recommended Action 8005 55249 NAS system LUN 0000 or Check the settings, and then LUN 0001 has the SLPR retry the operation. number different from the SLPR number set for the port. Severity Level Failure Level E 6 E 6 E 6 E 6 Port Name:%s 8005 55250 NAS system LUNs, from LUN Check the settings, and then 0005 to LUN 000A, are not retry the operation. set for SLPR 0.
Table 65 Error Codes — Part Code 8105 Part Code Error Number Error Message 8105 1002 The specified volume cannot Select another volume. be set as a command device or a component of a LUSE volume, because it is being used as a Continuous Access, XP Business Copy, XP Flex Copy, XP Auto LUN, or XP Snapshot volume. Select another volume.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 1011 An error occurred. If this problem persists, call technical support. The volume which links as an E expanded LU extend over CU#. The error does not occur normally because it is guarded in the screen. Contact the program maker. 2 8105 1012 LU path is set to a volume which links as an expanded LU.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8105 1025 The specified LU path does not exist. The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 8105 1028 The number of volumes you intend to combine into a LUSE volume exceeds the maximum. The Configuration information E has been already changed.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message 8105 1066 WWN number, which is not The Configuration information E registered, is specified. has been already changed. (When deleting, or changing) Check the settings and request the setting of the configuration information again. 6 8105 1067 You are trying to register the same host group as the existing one.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8105 1123 Command device security cannot be set to the specified volume because the volume is not a command device. The Configuration information E has been already changed. Failure Level 6 Check the settings and request the setting of the configuration information again. 8105 1124 An error occurred. If this problem persists, call technical support.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action 8105 1132 Failed to set the WWN because the number of WWNs exceeds the maximum that can be set in a port. The Configuration information E has been already changed. Failed to set the host mode because the number of host modes exceeds the maximum that can be set in a port. The Configuration information E has been already changed.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action 8105 1188 You cannot delete the specified system LU because the system LU is being used by the NAS package. To delete the system LU, shut down the NAS OS. Shut down the NAS OS, and E then retry. 8105 1189 Failed to delete the specified Delete a file system user LU because it is being configured on the user LU, used by the NAS package. and then retry.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 1352 Logical paths remain on the Fibre-MCU port. This operation may cause a fatal damage to the logical paths. Stop this operation. To continue this operation, remove the logical paths from the MCU port first. Since the port you are trying E to set is for Fibre Continuous Access, you need to delete the logical path, and then set.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 1601 This functionality is not available. Open Volume Management is required. Install the necessary program E product. When an SLPR is allocated, install a necessary program product for the SLPR. 8105 1904 The specified volume cannot Select another volume.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 2003 An error occurred during SVP processing. If this problem persists, call technical support. Use the SVP to check if the DKC is in the normal status, and then retry. If the same problem persists despite retrying, call technical support. E 2 8105 2005 An error occurred during SVP If this problem persists, call processing.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 2097 The host specified by the WWN is performing I/O operations. Stop executing I/Os, and then retry the operation. E 6 8105 2170 An error occurred during server processing. If this problem persists, call technical support. Stop the host I/O. W 6 8105 2204 Devices to be maintained Delete or suspend all pairs to E include journal volumes.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 2517 An XP Business Copy, Hitachi ShadowImage for z/OS, or XP FlashCopy Mirror, or XP Flex Copy pair is defined. Cancel the pair definition, and then retry the operation. If a high speed split is in progress, first suspend and then cancel the pair. Cancel the pair definition, E and then retry the operation.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 5030 The spreadsheet has not been Change the configuration at changed at all. least one line in the spreadsheet. W 0 8105 5060 The length of the character string is invalid. 8105 5061 The number of lines is invalid. The CSV file can have up to 70,000 lines. E 5 8105 5062 The size of the CSV file is invalid. Review the CSV file.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 5743 There is a difference between Correct the CU and LDEV. the current CU:LDEV and the specified CU:LDEV. W 0 8105 5744 The command device security Turn on the command device W switch cannot be turned on switch. because this is not command device. 0 8105 5745 The security switch on the Turn on the security switch on W port is off. Turn on the switch.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8105 5767 The LUN does not exist. Correct the LUN. W 0 8105 5768 There is a difference between Correct the LUN. the current LUN and the specified LUN. W 0 8105 5769 The group cannot be added. Correct the group ID. W 0 8105 5770 The port cannot be changed Set the port attribute to target W because the port is an in advance. initiator port.
Table 65 Error Codes — Part Code 8105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8105 6023 The SVP is busy. Wait for a while, and then retry the operation. If the same problem persists E despite retrying, call technical support. 3 8105 6513 A command was double started. Retry a little later. 6 8105 6524 The port information is inconsistent with PCB mode information. Correct the port information W or the PCB mode information.
Table 67 Error Codes — Part Code 8110 (continued) Part Code Error Number Error Message 8110 5627 8110 Recommended Action Severity Level Failure Level The file name should be from Correct the specified 1 to 32 characters. contents, and retry the operation. E 1 5628 Following characters cannot Correct the specified be used for the file name: " contents, and retry the \ / , : ; * ? < > | and space. operation. E 1 8110 5629 The file specified by [File Name on Client] does not exist.
Table 67 Error Codes — Part Code 8110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8110 9359 Do you want to install Java Web Start? Select the OK button for W continuing processing. Select the Cancel button when you want to stop. 8110 59036 Do you want to overwrite the To overwrite the file, select existing file? [OK]. Otherwise, select [Cancel].
Table 69 Error Codes — Part Code 8210 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8210 7440 An error occurred during processing. If this problem persists, call technical support. If this problem persists, call technical support.
Table 72 Error Codes — Part Code 8505 Part Code Error Number Error Message Recommended Action Severity Level 8505 2007 An error occurred during SVP If the same problem persists E processing. despite retrying, call technical support. If this problem persists, call Failure Level 2 technical support. 8505 5099 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action 8505 55010 An invalid SLPR No. was detected. Correct the SLPR No., and E then retry the operation. If this problem persists, call technical support. 5 8505 55011 An invalid CLPR Name was detected. CLPR No:%s (SLPR No:%s) Correct the CLPR Name, and E then retry the operation. If this problem persists, call technical support. 5 8505 55012 An invalid SLPR Name was detected.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8505 55021 The specified CU number is invalid. Specify the correct CU number, and then retry the operation. If this problem persists, call technical support. E 5 8505 55022 An attempt has been made to either register newly a CLPR that is already registered, or delete a CLPR that is not registered. Correct the CLPR settings, E and then retry the operation.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8505 55031 LUN cannot be set across plural SLPRs. Change the settings so that E the port list and the LU in the parity group are matched, and retry the operation. If the same problem persists despite retrying, call technical support. 5 8505 55032 The LUSE volume cannot be set across plural SLPRs.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action Severity Level 8505 56501 The login information for the partition management function has been initialized due to detection of conflicting information. Contact the storage administrator. (To the storage administrator: reconfigure the login information.) Contact the storage i administrator. (To the storage administrator: reconfigure the login information.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8505 58313 The configuration cannot be changed because the available XP Cache LUN Software size or the number of XP Cache LUN Software areas in the intended CLPR is insufficient. Check the XP Cache LUN Software size and the number of XP Cache LUN Software areas. Check the XP Cache LUN i Software size and the number of XP Cache LUN Software areas.
Table 72 Error Codes — Part Code 8505 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8505 58323 The CLPR that the parity groups belong to cannot be changed because the specified parity groups include only a part of the XP Continuous Access Asynchronous Software or TrueCopy Asynchronous for Mainframe pair volumes in a CT group. Specify the parity group so that all the pair volumes in CT group are contained.
Table 74 Error Codes — Part Code 8510 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8510 5030 The display information has not been changed. Specify what you want to register, and retry the operation. W 0 8510 5144 Some of the entered values are incorrect. Check the values and retry. Check the entered values and W retry. 0 8510 7060 An error occurred in client logic. If this problem persists, call technical support.
Table 74 Error Codes — Part Code 8510 (continued) Part Code Error Number Error Message Severity Level Failure Level 8510 55242 You cannot move the NAS Check the settings and retry system LUs (command device, the operation. failure information storage, FailSafe, and backup data) to other SLPRs. Change the setting. W 0 8510 55261 The concatenated parity Select another parity group, W group cannot be set across and then retry the operation. multiple CLPRs.
Table 74 Error Codes — Part Code 8510 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 8510 59067 A maximum of 256 SSIDs will be registered except for the duplicate SSIDs. Check the settings. W 0 8510 59068 Information from Partition Definition Check the settings. i 0 8510 59070 The LUSE volume is set across plural SLPRs. If you perform this operation, the storage partition administrator will become unable to operate.
Table 75 Error Codes — Part Code 9005 Part Code Error Number Error Message 9005 5099 9005 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 5201 This functionality is not available. Parallel Access Volume is required. Install the program product. E 6 9005 6001 An error occurred during SVP If this problem persists, call processing.
Table 75 Error Codes — Part Code 9005 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9005 7117 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 2 9005 8001 An error occurred while Retry the operation. If you get E connecting to the subsystem. the same message again, call Wait for a while, and then technical support. retry the operation.
Table 77 Error Codes — Part Code 9010 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9010 9303 There are no valid volumes. Check the device emulation type or the definition of the journal volume. W 0 9010 59341 In the environment where the If you want to apply the host is connected, the setting, click [Yes]. If not, performance of host I/O click [No]. might be decreased if the alias volume is added to more than one CU at a time.
Table 78 Error Codes — Part Code 9105 (continued) Part Code Error Number Error Message Recommended Action Severity Level 9105 5609 The R-VOL/T-VOL exists in a group which cannot include R-VOLs and T-VOLs. First, select [OK]. Next, W change the group attribute or delete the R-VOL/T-VOL from the group. Finally, retry the operation. 0 9105 5819 The specified port is not supported by this function. Specify a port supported by this function.
Table 79 Error Codes — Part Code 9107 Part Code Error Number Error Message Recommended Action Severity Level 9107 6012 An error occurred during SVP processing. If this problem persists, call technical support. An error occurred during SVP E processing. If this problem persists, call technical support. 9107 7060 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 80 Error Codes — Part Code 9110 (continued) Part Code Error Number Error Message Recommended Action Severity Level 9110 5618 The target logical device has Select [OK], check the current W already been defined to settings, and retry the another security group. Also, operation. the security group contains the same host in the target security group. 0 9110 5619 The R-VOL/T-VOL cannot be set to the specified security group.
Table 80 Error Codes — Part Code 9110 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9110 9082 Are you sure you want to To delete the host, select i delete the selected host which [Yes]. Otherwise, select [No]. was added by the user? 0 9110 9083 The specified group is To delete the group, select i registered in the security [Yes]. Otherwise, select [No]. group.
Table 81 Error Codes — Part Code 9205 (continued) Part Code Error Number Error Message 9205 6012 9205 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 6023 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 81 Error Codes — Part Code 9205 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9205 8121 This logical volume is an open volume. Specify a mainframe Volume. E 5 9205 8122 This logical volume is busy. Retry a little later. E 5 9205 8126 The logical volume is configured as a command device. Check the logical volume E configuration, and then retry the operation.
Table 82 Error Codes — Part Code 9207 (continued) Part Code Error Number Error Message Recommended Action 9207 5805 You cannot use the following Correct the pattern file name, W characters for pattern file and retry the operation. names: " \ / . , : ; * ? < > | Also, you cannot use multi-byte characters for pattern file names. 5 9207 5806 The maximum length of a pattern file name is 16 characters. Use 16 characters or less for a pattern file name.
Table 83 Error Codes — Part Code 9210 Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9210 7060 An error occurred during processing. If this problem persists, call technical support. If this problem persists, call technical support. E 2 9210 7442 There is an invalid value in the Volume Retention Manager information. If this problem persists, call technical support.
Table 84 Error Codes — Part Code 9211 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9211 6527 File access error. The destination directory E might contain a file that has the same name without Read/Write attribute. Specify another directory. 5 9211 6528 No pattern file was found. Review the pattern file name. W 5 9211 6529 File access error. If this problem persists, call technical support.
Table 85 Error Codes — Part Code 9505 (continued) Part Code Error Number Error Message 9505 7111 9505 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 3 7310 This error code is not registered. If this problem persists, call technical support.
Table 86 Error Codes — Part Code 9507 Part Code Error Number Error Message Recommended Action 9507 6012 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. Severity Level Failure Level E 3 Severity Level Failure Level Table 87 Error Codes — Part Code 9510 Part Code Error Number Error Message Recommended Action 9510 6516 R-VOLs exist on the RCU port. Release the R-VOLs that have W been set.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9605 5511 The program product is not installed. Install Program Product. W 5 9605 5809 The number of requests for Review LUs, and retry the combining LUs does not operation. match the number of the LUs. E 3 9605 6012 An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action 9605 8123 This function is not supported. Check the DKCMAIN E microcode version and the SVP microcode version, because these versions might be mismatched. 5 9605 8124 This logical volume is a mainframe volume. E 5 9605 8125 The attribute of the logical Review LDEV information, volume has been changed by and then retry. RAID Manager.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9605 8139 The specified volume is a P-VOL for XP Business Copy. Check the volume, and then retry the operation. E 5 9605 8141 This logical volume cannot be Check the volume, and then selected because it is used as retry the operation. a reserve volume for XP Auto LUN.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9605 56528 Storage partition Contact the storage E administrator cannot disable administrator or call technical the expiration lock, because support. the expiration lock is set to Enable by storage administrator. 5 9605 58404 The specified operation Retry the operation after the cannot be executed because process is completed.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message 9605 58423 9605 Recommended Action Severity Level Failure Level An error occurred during SVP If this problem persists, call processing. If this problem technical support. persists, call technical support. E 5 58424 The specified logical volume is blocked. Restore the logical volume.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action Severity Level 9605 58436 The access attribute of the logical volume has already been changed.
Table 88 Error Codes — Part Code 9605 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9605 58449 The capacity of the logical Do one of the following: E volume is not the same as 1. Using Customized Volume that of the external volume main window, execute the with which the logical volume Volume Initialize is mapped. operation on the external group to which the logical volume belongs. 2.
Table 89 Error Codes — Part Code 9607 (continued) Part Code Error Number Error Message Recommended Action Severity Level Failure Level 9607 7120 A parameter error occurred. If this problem persists, call technical support. If this problem persists, call technical support. E 5 9607 7121 A parameter error occurred. If this problem persists, call technical support. If this problem persists, call technical support.
Table 91 Error Codes — Part Code 10010 (continued) Part Code Error Number Error Message 10010 55641 10010 Recommended Action Severity Level Failure Level The current setting is not Reply to the message. applied. Apply the setting, and then retry the operation. W 5 55642 The path to the output folder Reply to the message. is invalid. (The first character of the path to the output folder shall be “/”.
2 Support and Other Resources Related Documentation • HP StorageWorks XP12000 Disk Array Owner's Guide • HP StorageWorks XP10000 Disk Array Owner's Guide • HP StorageWorks XP Remote Web Console User Guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System You can find these documents on the HP Manuals website: http://www.hp.com/support/manuals In the Storage section, click Storage Software and then select a product.
A Acronyms and Abbreviations Table 92 Acronyms and Abbreviations API application program interface CCI XP RAID Manager CHIP channel adapter CT consistency CTG consistency group CU control unit CV customized volume DASD direct-access storage device DFW DASD fast write ACP disk adapter DKC disk controller IP internet protocol L1, L2 level 1, level 2 LAN local-area network LBA logical block address LCP local control port LDEV logical device LU logical unit LUN logical unit
Table 92 Acronyms and Abbreviations (continued) 374 S-VOL secondary volume (Continuous Access), source volume (Hitachi ShadowImage for z/OS) SVP service processor T-VOL target volume storage system HP storage system VDEV virtual device WWN worldwide name Acronyms and Abbreviations