58 XP Performance Control Export Tool
Period during which monitoring data was collected onto the SVP (storing period).
Interval at which the monitoring data was collected (gathering interval).
XP Auto LUN collects statistics by the type of storing period: in short range and in long range. In
short-range monitoring, monitoring data between 1 and 15 days is stored in the SVP. In long-range
monitoring, monitoring data up to three months is stored in the SVP.
The show subcommand displays the storing period and gathering interval for these types of monitoring
data: in short range and in long range.
For example, the show command outputs the following information:
Short Range indicates the storing period and gathering interval of monitoring data stored in short
range. Long Range indicates those of monitoring data stored in long range. When running the Export
Tool, you can export monitoring data within these periods into files. If you use the shortrange or
longrange subcommand, you can also narrow the term of data to be exported (see ”The shortrange
subcommand” on page 67 or ”The longrange subcommand” on page 70).
From indicates the starting time for collecting monitoring data. To indicates the ending time for collecting
monitoring data.
Interval indicates the interval at which the monitoring data was collected (gathering interval. For
example, Interval : 15 min. indicates that monitoring data was collected at 15-minute intervals.
Storing periods output by the show subcommand is the same as the information displayed in the
Monitoring Term area of the Auto LUN XP pane (see Figure 10).
Figure 10 Information output by the show subcommand
The login command must execute before the show subcommand executes.
The group subcommand
Syntax
group{PhyPGD[Short|Long][[parity-group-id]:[parity-group-id]][...]|
PhyLDEV[Short|Long][[parity-group-id]:[parity-group-id]][...] |
PhyExG[[exg-id]:[exg-id]][...]|
PhyExLDEV[[exg-id]:[exg-id]][...]|
PhyProc[Short|Long]|
PhyCSW[Short|Long]|
PG[[parity-group-id|V-VOL-group-id|exg-id]:
[[parity-group-id|V-VOL-group-id|exg-id]][...]|
LDEV[[parity-group-id|V-VOL-group-id|exg-id]
[[parity-group-id|
V-VOL-group-id|exg-id]][...]|
Port[[port-name]:[port-name]][...]|
Short Range From: 2004/10/01 01:00 - To: 2004/10/01 15:00Interval : 1min
Long Range From: 2004/09/01 00:00 - To: 2004/10/01 15:00Interval : 15min
Remote Copy From: 2004/09/30 00:00 - To: 2004/10/01 15:00