HP StorageWorks XP LUN Configuration and Security Manager User Guide: HP XP12000 Disk Array HP XP10000 Disk Array HP 200 Storage Virtualization System (T1714-96030, June 2010)
• If you select a Fibre Channel channel adapter, the list displays information about Fibre Channel
ports.
Figure 24 Port table (Fibre Channel ports)
.
• Port Name: Port name. For more information, see Table 2, Table 3, Table 4, and Table 5.
• Type: Port‘s type. Fibre indicates a Fibre Channel port, which is used for connecting open-
system hosts.
• Host Speed: Fibre Channel port's data transfer speed. The unit is Gbps (gigabits per second).
• Addr (Loop ID): Port‘s address.
• Fabric: Indicates if a fabric switch is used.
• Connection: Topology. The default is FC-AL. However, you must be aware that some fabric
switches require you to specify the point-to-point topology. If your system uses a fabric switch,
check the fabric switch's documentation to determine whether the switch requires the point-to-
point topology.
• Attribute: Indicates whether the port is an initiator, target, RCU target, or external port.
• WWN: Host bus adapter's WWN.
• If you select an iSCSI channel adapter, the list displays information about iSCSI ports and iSNS
servers.
Figure 25 Port table (iSCSI ports and iSNS servers)
.
• Port Name: iSCSI port's name. For more information, see Table 2, Table 3, Table 4, and Table
5.
• IP Address: iSCSI port's IP address.
• Subnet Mask: Subnet mask.
• Gateway: Gateway address.
• Port No.: iSCSI port's number.
• Keep Alive Timer: Keep-alive timer value. The unit is seconds.
• iSNS Server: Indicates whether you can register the iSCSI port in the iSNS server.
• Enable: You can register the iSCSI port.
XP LUN Configuration and Security Manager User Guide 73