4. Right-click any point in the FC Switch Information list, and select Specify User Information. The
Specify Authentication Information pane appears.
Figure 69 Specify Authentication Information pane
.
Specify the following user information for the host you want to allow to connect:
• User Name: Fibre Channel switch's user name, up to 16 characters. You can use alphanumeric
characters in a user name.
• Secret: Secret (that is, a password used in CHAP authentication) between 12 to 32 characters.
You can use alphanumeric characters.
• Re-enter Secret: Specify the secret, again, for confirmation.
5. Click OK.
6. Click Apply. A confirmation message appears.
7. Click OK. Settings are applied to the array.
Clearing a Fibre Channel switch's user information
1. Start XP LUN Configuration and Security Manager Software, and display the Authentication pane
(Figure 30).
2. In the Port tree, double-click the Subsystem folder. If the array contains Fibre Channel adapters,
the Fibre folder appears below the Subsystem folder.
3. In the Port tree, double-click the Fibre folder. Information about the Fibre Channel switch appears
in the FC Switch Information list.
XP LUN Configuration and Security Manager Software operations136