HP StorageWorks XP LUN Configuration and Security Manager User Guide: HP XP12000 Disk Array HP XP10000 Disk Array HP 200 Storage Virtualization System (T1714-96030, June 2010)
authentication by Fibre Channel switches with CHAP, the connection results are as follows, unless
otherwise noted.
Table 18 Combinations of Fibre Channel settings and connection results
Connection resultsFibre Channel switch
settings
Port settings
Fibre Channel switch's
user information
Authentication: at Fibre
Channel switch
Connected if the au-
thentication of the
Fibre Channel switch
succeeded
RegisteredRegisteredEnable
Failed to be authentic-
ated and cannot be
connected
Not registeredRegisteredEnable
Failed to be authentic-
ated and cannot be
connected
RegisteredNot registeredEnable
Connected without
authentication of the
Fibre Channel
switch
2
—
1
—
1
Disable
1
This item does not affect the connection results, or cannot be specified.
2
If a Fibre Channel switch is configured for authentication by ports with CHAP, authentication of the host fails. To allow such
a Fibre Channel switch to connect to the port without authentication, do not configure it for authentication by ports with CHAP.
For more information about authentication of hosts, see Authentication of Fibre Channel switches.
Specifying a Fibre Channel port's information
To perform user authentication in Fibre Channel environments, you must specify information for the
Fibre Channel ports of the array.
1. Start XP LUN Configuration and Security Manager Software, and display the Authentication pane
(Figure 30).
2. In the Port tree, double-click the Subsystem folder. If the array contains Fibre Channel adapters,
the Fibre folder appears below the Subsystem folder. The port's information appears in the Port
Information list.
XP LUN Configuration and Security Manager User Guide 133