HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)
DescriptionItem
The result of operation.
Normal end: Normal end
Error(xxxx-yyyyy): Abnormal end
xxxx: Part codeyyyyy: Error code
Result
The number of the volumes where the Extent operation is executed.Num. of LDEVs
VMA operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00, [LSE],VMA,,Normal end,Seq.=xxxxx
+{CU:LDEV,Result}=[{0x00:0x01,Normal end},{0x00:0x02,Error(9605-8122)},{0x00:0x03,Normal end},
{0x00:0x03,Normal end},{0x00:0x03,Normal end}],Num. of LDEVs=XXX
[LSE]
LUN Security Extension function
VMA
Volume Management Area (VMA) operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 30 Detailed information for VMA operation
DescriptionItem
The CU number and the LDEV number of the volume where the Extent operation
is executed.
CU:LDEV
The result of operation.
Normal end: Normal end
Error(xxxx-yyyyy): Abnormal end
xxxx: Part codeyyyyy: Error code
Result
The number of the volumes where the Extent operation is executed.Num. of LDEVs
LUN Security XP Extension function76