HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)

DescriptionItem
The threshold in case of prioritized port and the upper limit value in case of non-
prioritized port. This value is output only when the threshold or the upper limit value
is set.
Threshold/Upper Limit
The type of rate used for upper limit control and threshold control.
IOPS: I/O rate, KB/s: Transfer rate
This value is output when the threshold or the upper limit value is set.
Mode
The number of ports that the setting is changed.Num. of Ports
Set Prio WWN operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[PFC],Set Prio WWN,,Normal end,Seq.=xxxxx
+{WWN,Priority,,Mode}=[{0xXXXXXXXXXXXXXXXX,Non-Prio,XXXXXXXX,IOPS}],Num of WWNs=1
[PFC]
Performance Control function
Set Prio WWN
Set Priority (Prio) World Wide Name (WWN) operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 204 Detailed information for Set Prio WWN operation
DescriptionItem
Indicates WWN of the host bus adapter. WWN is a 16-digit number in the hexa-
decimal format.
WWN
The attribute set to the host bus adapter.
Prio: Prioritized WWN, Non-Prio: Non-prioritized WWN
Priority
The upper limit value when the attribute is set to non-prioritized WWN.
This value is not output when the attribute is set to prioritized WWN.
Upper Limit
The type of rate used for the upper limit control.
IOPS: I/O rate, KB/s: Transfer rate
This value is not output when the attribute is set to prioritized WWN.
Mode
The number of WWNs of the host bus adapters that the setting is changed.Num. of WWNs
Performance Control function222