HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)

Maintenance function
Replace
Replace operation
Easy-Replace
Easy-Replace is the parameter output when easy replacing a PDEV.
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 156 Detailed information for Replace operation
DescriptionItem
The name of the parts (EPO SE, PCI CON/BOX, DKC-PANEL, PSxx, BATTERYxx,
AC BOX-x, PDU-xx, nFANx, THxx, DKCMNx, SSVP, SVP, HDDFANxx or ALPAxx)
specified to be replaced.
Parts name
The port which SFPs are inserted.SFP
The number of inserted SFPs.Num.of SFPs
The mounting location of the PCB, (Channel Adapter (CHA), Disk Adapter (DKA),
cache memory, CM, SM, cache switch, MIX or BASE) to be replaced.
PCB
When replacing multiple PCBs and some of the PCBs to be replaced had failures,
the mounting locations of the failed PCBs are indicated. In such case, Warning is
output as the result of the process.
NOTE:
This information is not output when there are no failed PCBs.
Failed
The number of PCBs to be replaced.Num. of PCBs
The mounting location of the PDEVs (physical devices) to be replaced.Physical Device (PDEV)
The status of copy process when replacing PDEVs. This information is output only
when replacing PDEVs.
Restore Data: Data recovery from spare disk, Correction Copy: correction copy
Copy
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This
information is output only when replacing PDEVs.
Diagnosis
Micro Program is output only when microprogram update is skipped when replacing
PDEVs. This information is output only when replacing PDEVs.
Micro Program
The number of PDEVs to be replaced. This information is output only when easy
replacing PDEVs.
Num. of PDEV
The mounting location of the fibre switches to be replaced.FSW
The number of fibre switches to be replaced.Num. of FSWs
Maintenance function172