HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)

Set Security Switch operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx,00:00,[LUNM],Set Security Switch,,Normal end,
Seq.=xxxxx
+{Port,Switch}=[{XX,Disable},{XX,Enable}],Num.of Ports=2
[LUNM]
LUN Manager function
Set Security Switch
Set Security Switch operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 145 Detailed information for Set Security Switch operation
DescriptionItem
The name of the port where the LUN security setting is changed.Port
Indicates whether the LUN security setting is enabled or disabled.
Disable or Enable is output.
Switch
The number of ports where the LUN security setting is changed.Num. of Ports
Set Speed Mode operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[LUNM],Set Speed Mode,,Normal end,Seq.=xxxxx
+CHA=CHA-1E
++{Port Block,Mode}=[{A,High Speed/MIX},{B,High Speed/MIX},{C,Standard},{D,Standard}],
Num. of Blocks=4
+CHA=CHA-1H
++{Port Block,Mode}=[{A,Standard},{B,High Speed/MIX}],Num. of Blocks=2
+Num. of CHAs=2
[LUMN]
LUN Manager function
Set Speed Mode
Set Speed Mode operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
XP Audit Log reference guide 163