HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)
LUN Manager function
Change Host Group
Change Host Group operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 120 Detailed information for Change Host Group operation
DescriptionItem
The name of the port where the host group is created.Port
The host group number where the name or host modes have been changed.HostGrpID
The name of the host group. If the name is changed, the name after change
is indicated.
HostGrpName
The number of host groups where the settings have been changed.Num. of Host Groups
Change iSCSI name operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[LUNM],Change iSCSI name,,Normal end,Seq.=xxxxx
+{Port,HostGrpID,iSCSI name,Change iSCSI name,Name}=[{1E,0x01,iqn.xxxxx,iqn.yyyyy,aaaaa},
{3E,0x01,iqn.mmmmm,iqn.nnnnn,bbbbb}],Num. of iSCSI name=2
[LUNM]
LUN Manager function
Change iSCSI name
Change iSCSI name operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 121 Detailed information for Change iSCSI name operation
DescriptionItem
The name of the port where the iSCSI name has been changed.Port
The host group number where the iSCSI name has been changed.HostGrpID
LUN Manager (LUNM) function146