HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)
Detailed information displays for this operation, as shown in the following table.
Table 99 Detailed information for Uninstall operation (uninstalling a cache memory module)
DescriptionItem
The mounting location of the PCB for cache memory.CM
The capacity of CMG.CMG
The capacity of cache memory.Size
The capacity of On-Demand.On-Demand
The number of cache memory.Num. of CMs
The capacity of Cache Residency.DCR available size
The capacity of PCR.PCR available size
The CLPR number.CLPR
The capacity of the cache memory allocated to CLPR.Cache size
The capacity of Cache Residency allocated to CLPR.DCR size
The number of extents allocated to CLPR.Extent Number
The capacity of the PCR allocated to CLPR.PCR size
The number of CLPR.Num. of CLPRs
The mounting location of the shared memory.SM
The slot position of the shared memory module.Slot
The capacity of the shared memory module.Size
The number of shared memory modules.Num. of SMMs
The mounting location of the battery.Battery
Indicates the installation or the uninstallation of the battery.
Install: Install battery, Uninstall: Uninstall battery.
Define
The number of battery pairs.Num. of Battery Pairs
NOTE:
Only the changed items will be output.
Example 4 (Uninstalling a shared memory module)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Uninstall,,Normal end,Seq.=xxxxx
+{SM,Slot,Size}=[{1SA/2SB,1,2048},{1SC/2SD,7,1024}],Num of SMMs=2
+{PP Flag}={{<HMRCF/HOMRCF/HRC/HORC/HUR/HIHSM/Hi-Copy Extension>,
<Flash Copy V2/COW Snapshot>},Num of PP Flags=2
+VFS SYS Area=Basic
+Max Number of CUs=255
+{Battery,Define}=[BATTERY13/BATTERY23,Install],Num. of Battery Pairs=1
XP Audit Log reference guide 131