HP StorageWorks XP Audit Log reference guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200 Storage Virtualization System (5697-8004, March 2009)

DescriptionItem
The number of parity groups.Num. of PGs
The B4 number.B4
The spare drive number.SPARE
The number of spare drives.Num. of SPAREs
NOTE:
Only the changed items will be output. In the recovery process, the detailed information of the process
is not output when the setting of the installation before the process has completed. However, the setting
of the recovery process is output as the detailed information when the setting of the installation before
the process has not completed.
Example 3 (Installing additional cache memory)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Install,,Normal end,Seq.=xxxxx
+{CM,CMG,Size,On-Demand}=[{Basic,2048,4096,0,},{Option,2048,2048,0}],Num. of CMs=2
+DCR available size=2048
+PCR available size=2048
+{CLPR,Cache size,DCR size,Extent Number,PCR size}={CLPR1,4096,0,4096,0},Num. of CLPRs=1
+{SM,Slot,Size}={1SA/2SB,1,1024},Num. of SMMs=1
+{Battery,Define}=[BATTERY13/BATTERY23,Install],Num. of Battery Pairs=1
[Install]
Install function
Install
Install operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 64 Detailed information for Install operation (installing additional cache memory)
DescriptionItem
The mounting location of the PCB for cache memory.CM
The capacity of CMG.CMG
The capacity of cache memory.Size
The capacity of On-Demand.On-Demand
The number of cache memory.Num. of CMs
Install function104