HP StorageWorks XP Audit Log reference guide for the XP12000/XP10000 and SVS 200 (5697-7157, November 2007)

Table Of Contents
23 Remote Control Unit (RCU) function
Add Path operation
Example 1 (CU Free is used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Add Path,,Normal end,Seq.=xxxxx
+{S/N,Path Gr. ID,Controller ID}={99999,Default,4}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num. of Port Pairs=8
Example 2 (CU Free is not used)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[RCU],Add Path,,Normal end,Seq.=xxxxx
+{S/N,SSID,Controller ID}={99999,0x0004,4}
++{MCU Port,RCU Port}=[{1E,3E},{5E,7E},{1F,3F},{5F,7F},{1G,3G},{5G,7G},{1H,3H},{5H,7H}],
Num. of Port Pairs=8
[RCU]
Remote Control Unit function
Add Path
Add Path operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in the following table.
Table 171 Detailed information for Add Path operation
DescriptionItem
Indicates a serial number of the device.S/N
The path group ID. When the path group ID is default setting, Default
is output.
Path Gr. ID
The controller ID.Controller ID
The SSID.SSID
The port number of MCU.MCU Port
The port number of RCU.RCU Port
XP Audit Log reference guide 187