HP StorageWorks XP Audit Log reference guide for the XP12000/XP10000 and SVS 200 (5697-7157, November 2007)

Table Of Contents
DescriptionItem
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This
information is output only when replacing PDEVs.
Diagnosis
Micro Program is output only when microprogram update is skipped when replacing
PDEVs. This information is output only when replacing PDEVs.
Micro Program
The number of PDEVs to be replaced. This information is output only when easy
replacing PDEVs.
Num. of PDEV
The mounting location of the fibre switches to be replaced.FSW
The number of fibre switches to be replaced.Num. of FSWs
Restore operation
Example 1 (Restoring a PCB)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance],Restore,,Normal end,Seq.=xxxxx
+PCB=[CHA-1P],Num. of PCBs=1
+PDEV=HDD00-01
Example 2 (Restoring an LDEV)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance],Restore,,Normal end,Seq.=xxxxx
+PG=[1-1],Num. of PGs=1
+PG=[E1-1],Num. of PGs=1 –> in case of an external volume
+PG=[V1-1],Num. of PGs=1 –> in case of a vertual volume
+LDEV=[0x00-0x01],Num. of LDEVs=2
[Maintenance]
Maintenance function
Restore
Restore operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 158 Detailed information for Restore operation
DescriptionItem
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter
(DKA), cache memory (CM), shared memory (SM), cache switch (CSW), MIX
or BASE) to be restored.
PCB
The location of the PDEV to be restored.PDEV
XP Audit Log reference guide 173