HP StorageWorks XP Audit Log reference guide for the XP12000/XP10000 and SVS 200 (5697-7157, November 2007)

Table Of Contents
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance], Replace,Easy-Replace,Normal end,
Seq.=xxxxx
+PDEV={HDDR03-01},Num. of PDEV=1
Example 6 (Replacing a fibre switch)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Maintenance], Replace,,Normal end,Seq.=xxxxx
+FSW=[FSWR04-LL,FSWR05-LL],Num. of FSWs=2
[Maintenance]
Maintenance function
Replace
Replace operation
Easy-Replace
Easy-Replace is the parameter output when easy replacing a PDEV.
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 157 Detailed information for Replace operation
DescriptionItem
The name of the parts (EPO SE, PCI CON/BOX, DKC-PANEL, PSxx, BATTERYxx,
AC BOX-x, PDU-xx, nFANx, THxx, DKCMNx, SSVP, SVP, HDDFANxx or ALPAxx)
specified to be replaced.
Parts name
The port which SFPs are inserted.SFP
The number of inserted SFPs.Num.of SFPs
The mounting location of the PCB, (Channel Adapter (CHA), Disk Adapter (DKA),
cache memory, CM, SM, cache switch, MIX or BASE) to be replaced.
PCB
When replacing multiple PCBs and some of the PCBs to be replaced had failures,
the mounting locations of the failed PCBs are indicated. In such case, Warning is
output as the result of the process.
NOTE:
This information is not output when there are no failed PCBs.
Failed
The number of PCBs to be replaced.Num. of PCBs
The mounting location of the PDEVs (physical devices) to be replaced.Physical Device (PDEV)
The status of copy process when replacing PDEVs. This information is output only
when replacing PDEVs.
Copy
Restore Data: Data recovery from spare disk, Correction Copy: correction copy
Maintenance function172