HP StorageWorks XP Audit Log reference guide for the XP12000/XP10000 and SVS 200 (5697-7157, November 2007)

Table Of Contents
[Install]
Install function
Uninstall
Uninstall operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 101 Detailed information for Uninstall operation (uninstalling a shared memory module)
DescriptionItem
The mounting location of the PCB for shared memory.SM
The slot position of the shared memory module.Slot
The capacity of the cache memory module.Size
The number of shared memory modules.Num of SMMs
The flags of the options.PP Flag
The number of the flags of the options.Num of PP Flags
The area of VFS SYS.VFS SYS Area
The maximum number of CUs.Max Number of CUs
The mounting location of the batteryBattery
Indicates the installation or the uninstallation of the battery.Define
Install: Install battery, Uninstall: Uninstall battery.
The number of battery pairs.Num. of Battery Pairs
NOTE:
Only the changed items will be output.
Example 5 (Uninstalling a power supply)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Uninstall,,Normal end,Seq.=xxxxx
+Redundant=EQUIP
[Install]
Install function
Uninstall
Install function132