HP StorageWorks XP Audit Log reference guide for the XP12000/XP10000 and SVS 200 (5697-7157, November 2007)

Table Of Contents
Detailed information displays for this operation, as shown in the following table.
Table 67 Detailed information for Install operation (installing additional power supply)
DescriptionItem
The status of additional cluster power supply.Redundant
EQUIP: Installed, NOT EQUIP: Not installed.
Example 6 (Installing additional battery)
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Install,,Normal end,Seq.=xxxxx
+Battery=[BATTERY13/BATTERY23],Num. of Battery Pairs=1
[Install]
Install function
Install
Install operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (000000 to 999999)
Detailed Information
Detailed information displays for this operation, as shown in the following table.
Table 68 Detailed information for Install operation (installing additional battery)
DescriptionItem
The mounting location of the batteryBattery
The number of battery pairs.Num. of Battery Pairs
Install CV operation
user-name,xx,YYYY/MM/DD,HH:MM:SS:xxx, 00:00,[Install],Install CV,,Normal end,Seq.=xxxxx
+{PG,CU:LDEV,SLOT,Emulation,Size,Unit,SSID}=[{1-1-(1),0x00-0x00,-,OPEN-V,500,MB,0x0004},
{1-1-(1),0x00-0x01,-,OPEN-V,500,MB,0x0004},],Num. of LDEVs=2
[Install]
Install Function
Install CV
Install Customized Volume (CV) operation
No parameter or Non Format
XP Audit Log reference guide 107