HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
0003 1198
Since a path is defined to
aCross-systemCopyLU,
you cannot set high-speed
mode.
Please correct the settings,
and then retry.
E
6
0003 1199
When defining paths from
iSCSI ports, you can only
define paths to open-systems
volumes.
Please correct the settings,
and then retry.
E
6
0003 1201
The selection of High Speed
mode/MIX m od
eisinvalid.
The specifie
dportcannot
be changed t
o High Speed
mode/MIX mode.
Change the parameter to
a path where the High
Speed mode/
MIX m ode
can be set,
and then retry
the operat
ion.
E
6
0003 1203
High Speed mode/MIX
mode was specified.
However, there are
addresses to which High
Speed mode/MIX mode
cannot be set in the Fibre
Addresses of the specified
ports.
The Configuration
information has been
already changed.
Please check the settings
and request the setting of the
configuration information
again.
E
6
0003
12 04
High Speed mode/MIX
mode was specified.
However, there are
topologies to which
High Speed mode/MIX
mode cannot be set in the
topologies of the specified
ports.
The Configuration
information has been
already changed.
Please check the settings
and request the setting of the
configuration information
again.
E
6
0003 1350
You could not add the path
to the initiator or external
port.
To ad
d a path, change the
attribute of the specified port
to Target or RCU T arget.
E
6
0003 1351
The high-speed or
initiator/external mix
mode can not be set to the
specified port because of
the attribute of the p ort.
Cannot set to high-speed
mode because the
port attributes are
mixed, or cannot set to
internal/external mix mode
because the combination of
port attributes is different.
Check the port attributes,
and then retry the operation.
E
6
0003 1352
Logical paths remain on
the Fibre-MCU port. This
operation may cause a fatal
damage to the logical paths.
Please stop this operation.
If you want to continue this
operation, please remove
the logical paths from the
MCU port first .
Since the port you are trying
to set is for Fibre Continuous
Access, you need to delete
the logical path, and then
set.
E
6
38