HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
9505 6515
Serverless Backup is
running, but the host
I/O operations might be in
progress. Please stop the
host I/O.
Please stop the host I/O.
W
5
9505 7060
An error occurred during
SVP processing. If this
problem persists, please call
technical suppor t.
If this problem persists,
please call technical
support.
E
3
9505
7111
An error occurred during
SVP proces
sing. If this
problem pe
rsists, please call
technica
lsupport.
If this problem persists,
please call technical
support.
E
3
9505 7310
This error code is not
registered.
If this problem persists,
please call technical
support.
E5
9505 7430
The specied por ts are
not the target of Serverless
Backup or are not equipped.
Please specify the ports
which are the target of
Serverless Backup.
E
6
9505 7431
The port
type of one or more
ports wh
ose bre PCB mode
is set t
ohighspeedisnot
changed to the External. If
you intend to change the
port t
ype of the ports whose
bre P
CB mode is high
spee
d to the External, make
sure
that you change the
port type of all the ports to
the External.
If you intend to change the
port t ype of the ports whose
bre PCB mode is set to
high speed to the External,
make sure that you change
theporttypeofalltheports
to the External at the same
time when you set the bre
PCB mode to high speed.
E5
9505 7432
The bre PCB mode is
set to high speed, but the
parameters of the external
ports are not the same.
Make sure that all the
external ports whose bre
PCB mode is set to high
speed hav e the same
parameter setting.
E5
9505 8001
An error occurred while
connecting to the subsystem.
Please retry a little later.
Retry the operation. If
yougetthesamemessage
again, please call technical
support.
E
3
9505 8002
A
communication time-out
e
rror occ urred in the
subsystem. Please wait for
a while, and then retry the
operation.
Please retry a little later.
E
3
9505 8102
This function is not
supported.
Check the DKCMAIN
microcode version and the
SVP microcode version,
because these versions
might be mismatched.
E
3
9505 55582
The specied CU group is
invalid.
Please specify CU group 0.
E5
368
HP StorageWorks XP Remote Web Console for Storage System M essages and Error Codes