HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
8105
118 4
The port information is
inconsistent with PCB mode
information.
Please correct the por t
information or the PCB
mode information.
W
0
8105 1188
You cannot delete the
specied system LU because
the system LU is being used
by the NAS package. To
delete the system LU, shut
down the NAS OS.
Please shut down the NAS
OS, and then retry.
E
2
8105 1189
Failed to de
lete the specied
user LU beca
use it is being
used by the N
AS package.
To delete the specied user
LU, delete the le system
congured on the LU that is
set by this user LU.
Please delete a le system
congured on the user LU,
and then retry.
E
6
8105 1193
You cannot add paths to
Continuous Access/Business
Copy/Cross-system Copy
pair volumes.
Please correct the settings,
and then retry.
E
6
8105 1198
Since a path is dened to
an external LU, you cannot
set high-speed mode.
Please correct the settings,
and then retry.
E
6
8105 12 01
The sel
ection of High Speed
mode/MIX mode is invalid.
The specied port cannot
be changed to High Speed
mode/
MIX mode.
Change
the parameter to
apathw
here the High
Speed mode/MIX mode
can be set, and then retry
the operation.
E5
8105 1203
High Speed mode/MIX
mode was specied.
However, there are
addresses to which High
Speed mode/MIX mode
cannot be set in the Fibre
Addresses of the specied
ports.
The Conguration
information has been
already chang ed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105 12 0 4
High Speed mode/MIX
mode was specied.
However, there are
topologies to which
High Speed mode/MIX
mode cannot be set in the
topologies of the specied
ports.
The Conguration
information has been
already chang ed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105 1350
Add path to the initiator
port failed.
Theportyouaretryingto
set is for Fibre Continuous
Access. You need to change
the attribute when adding
apath.Attribute(TarGetor
RCU TarGet)
E
2
Remote Web Console error codes