HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
7105 56 25
You cannot create another
pair, because the number of
pairs in the group exceeds
the maximum.
Please select the OK button.
i
0
7105 5626
The specified volume cannot
be used because it is
write-protected by Volume
Retention.
Please select the OK button.
i
0
7105
5654
This operation has been
rejected. The specified
volume(s) are being used by
Cross-system Copy.
Specify other volume(s), or
release the Cross-system
Copy setting.
i
0
7105 5656
The specified volume(s) are
Cross-system Volumes and
cannot be used to create a
pair.
Specify the volume(s) which
are not Cross-system Copy
volume(s).
i
0
7105 6502
Processing in progress.
Please wait for a while, and
then retry the operation.
Wait for a while, and retry
the operation.
i
0
7105 6503
Thevolumestatusisbeing
changed to simplex.
Wait for a while, and retry
the operation.
i
0
7105 6520
The operation was rejected.
This is b ecause the specified
volumes are defined in the
Security Group, and the
Security Group does not
allow the volumes to b e
R-Vols or T-Vols.
Take one of the following
actions:
• Change the attr ibute
of the Security Group
so that the specified
volumes can be R-Vols or
T-Vols.
• Release the specified
volumes from the Security
Group so that the
volumes can be R-Vols or
T-Vols.
i
0
7105 7310
This error code is not
registered.
If this problem persists, call
technical support.
W
0
7105 8500
The program product is not
installed.
Che
ck if the necessary key
for
the program product is
ins
talled.
i
0
7105 8501
The command was rejected,
because a status transition
was in progress.
Wait for a while, and retry
the operation.
i
0
7105 8502
You cannot reserve the
volume, because a
Continuous Access pair
exists in the same subsystem
frame.
Delete the Continuous
Access pair.
i
0
7105 8503
You cannot create the new
pair, because a Continuous
Access pair exists in the
same subsystem frame.
Delete the Continuous
Access pair.
i
0
Remote Web Console error codes