Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6610 59153
The journal volume cannot
be deleted because the
status of the mirror of the
journal group is Activ e .
Change the status of the
mirror of the journal group
to Stop or Initial, and then
retry the operation.
W0
66 1 0 5932 1
No more journal groups can
be added to the specified
extended consistency group
(EXCTG) .
Check the number of journal
groups in the specified
extended consistency group
(EXCTG).
W
0
66 1 0 59322
There are no
valid
extended co
nsistency
groups (EXC
TG).
Check whether all extended
consistency groups (EXCTG)
are used by other program
products.
W
0
66 1 0 59323
The entered parameter is
invalid.
The serial number, the
controller ID, or the journal
group to be added is not
specified.
Check the entered
parameter.
W
0
6610
59324
Some of the specified
journal groups belong to an
extended consistency group
(EXCTG). The timer type for
journal groups which belong
to EXCTG must be System.
Check whether the specified
journal groups include
journal groups which belong
to an extended consistency
group (EXCTG).
W
0
66 1 0 59325
Apairw
hich is ready for
Delta r
esync cannot be
creat
ed under the current
statu
softhespecified master
journ
al group. Check the
status of the specified master
journal group.
Check the status of the
specified master journal
group.
W
0
66 1 0 59326
Specify a mirror ID other
than 0 if you create a pair
ready for Delta resync.
Specify a mirror ID other
than 0.
W
0
66 1 0 59327
You cannot specify [Entire]
or [None] to the Initial copy
mode under the current
status of the specified master
journal g roup. Check the
status of the specified master
journal group.
Check the status of the
specified master journal
group.
W
0
66 1 0 59328
The journal volume cannot
be deleted because the
attribute of the mirror for
the journal group is master
and the status of the mirror
is Hold.
Change the status of the
mirror of the journal group
to Initial, and then retry the
operation.
W0
66 1 0 59329
The serial number of the
local DKC is entered. Select
the check box when you
add the journal group of the
local DKC to the extended
consistency group (EXCTG).
Select the check box when
you add the journal group
of the local DK C to the
extended consistency group
(EXCTG).
W
0
284