HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6610 59010
WARNING:
Initial copy mode None is
selected for some volume
pair. Are you sure that the
primary data volume and
the secondar y data volume
of the pair are already
synchronized?
Check the contents of the
primary and secondary
volumes. If the contents
match, select [Yes].
Otherwise, select [No].
W
0
6610 59013
The specified file a lready
exists. Do you want to
overwrite this file?
To overwrite the file, select
[Yes]. Otherwise, select
[No].
W
0
6610 59026
ThesameDKCisspecified
more than once. Check the
DKC setting.
Check the DKC setting.
W
0
6610 59030
The monitoring data saved
at present will be deleted.
To continue the operation,
select [OK]. To cancel the
operation, select [Cancel].
Please note that the current
monitoring data will be
deleted if you change the
setting of monitoring switch.
If necessary, use Export Tool
of Performance Monitor to
export the monitoring data
file.
i
5
6610 59031
The monitoring data saved
at present will be deleted
when the monitoring switch
is set to Enable the next
time.
To continue processing,
select [OK]. To stop
processing, select [Cancel].
Note that the monitoring
data saved at present will be
deleted when you change
the setting of the m onitoring
switch. If necessary, sav e
the monitoring data by
using the Export Tool.
i
5
6610
59040
You cannot add journal
volumes because Universal
Replicator for Mainframe is
not installed.
Purchase a license for
Universal Replicator for
Mainframe, and then install
it.
W
0
6610
59041
Warning:
A mainframe volume is
included in the journal
volumes to be deleted.
Please note the following
points if you have made
volume pairs by using this
journal group before.
• The mainframe volume
will be blocked.
• The mainframe volume
needs to be formatted
when you use the volume
as a non-journal volume.
• The CU number and
the LDEV number of the
mainframe volumes are
If you want to delete th e
journal volume, select [Yes].
If you do not want to delete
the journal volume, select
[No].
It is recommended that you
record the CU number and
the LDEV number of the
mainframe volume.
W
0
Remote Web Console error codes