651 0 59112
The CLPR number of the
specied data volume is
different from the CLPR
number of the data volume
in the Preset list. In this
operation, please specify
only one CLPR number.
Please specify only the
volume that has th e same
CLPR number as the CLPR
numberofthevolumeinthe
Preset list.
W
5
651 0 59113
TherearetwoormoreCLPR
numbers for the specied
volume, or you tried to
register a volume different
from the CLPR number of
an existing volume. Two or
more CLPR numbers cannot
exist in one journal group.
Please check the CLPR
number of the specied
volume, and check the CLPR
numbers of any existing
volumes. Specify the volume
so that there is only one
CLPR number in the journal
group.
W
5
651 0 59115
The number of presets may
have exceeded the limit, or
too large number of data is
selected.
If there are some presets,
check the number. If it is too
large, clear the presets by
selecting [Apply] and retry
the oper
ation. If there is no
preset
,toolargenumberof
data is
selected. Reduce the
number
of data and retry
the op
eration.
W
5
651 0 59116
The specied function is not
supported by the current
micropro gram version.
Check the microcode version
of the DKCMAIN, and then
call technical support.
W
0
651 0 5911 9
The current microprogram
version does not allow you
to change options for a
journal group in the Active
status.
Check the microcode version
of the DKCMAIN, and then
call technical support.
W
0
6510 59153
The journal volume cannot
be deleted because the
status of the mirror of the
journal group is Activ e .
Change the status of the
mir
ror of the journal group
to S
top or Initial, and then
re
try the operation.
W
0
651 0 59323
The entered parameter is
invalid.
The serial number, the
controller ID, or the journal
group to be added is not
specied.
Check the entered
parameter.
W
0
651 0 59325
Apairwhichisreadyfor
Delta resync cannot be
created under the current
status of the specied master
journal g roup. Check the
status of the specied master
journal group.
Check the status of the
specied master journal
group.
W
0
651 0 59326
Specify a mirror ID other
than 0 if you create a pair
ready for Delta resync.
Specify a mirror ID other
than 0.
W0
27 4