HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6505 58 627
The specified operation
failed because the
command device was
not registered or has been
blocked.
Check the status of the
command device.
6505 58 62 8
Journal groups cannot be
added to the specified
extended consistency group
(EXCTG), because different
journal group attributes
coexist in the specified
EXCT G.
Check the attribute of
the journal groups in
the specified extended
consistency group (EXCTG).
W0
6505 58 62 9
The specified operation
failed because of a
temporary path failure.
Retry the operation. If this
problem persists, please call
technical suppor t.
If this problem persists call
technical suppor t.
6505 58683
The operation failed
because the Continuous
Access Journal or the
Universal Replicator for
Mainframe function of the
secondary subs y stem does
not support the Delta resync
function.
Check the DKCMAIN
microcode version of the
secondary storage system,
call technical support,
and confirm whether the
Continuous Access Journal
or the Universal Replicator
for Mainframe function
supports the Delta resync
function.
W
0
6505
58684
The Add Pair (P aircreate)
operation to get ready for
Delta resync failed. The
specified primar y data
volume should meet the
following requirements.
• The specified volume
is a secondary data
volume for Continuous
Access Synchronous or
TrueCopy for Mainframe
Synchronous.
• The pair status of
Continuous Access
Synchronous or
TrueCopy for Mainframe
Synchronous is PAIR or
Duplex.
Check the status of the
primary data volume in
the Continuous Access
window or the TrueCopy for
Mainframe window.
W
0
260