HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6505 58 613
The command device is
specified incorrectly.
Check whether the specified
CU number and the
LDEV number indicates
acommanddevice.
W
0
6505 58 614
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the specified
journal group was not
registered.
Check whether the specified
journal group is registered.
W0
6505 58 615
Journal gro
ups cannot be
added to th
eextended
consisten
cy group (EXCTG),
because the specified mirror
ID was not registered in the
specified
journal group .
Check the mirror ID of the
specified journal group.
W
0
6505 58 616
The specified journal
group cannot be added to
extended consistency group
(EXCTG) .
Check the status of the
specified journal group.
W
0
6505 58 617
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the attributes of
the EXCTG and the journal
group are different.
Check the attributes of
the specified extended
consistency group (EXCTG)
and the journal group.
W
0
6505 58 618
Journal groups cannot be
added to the extended
consistency group (EXCTG),
bec
ause the timer type of
the
specified journal group
was
not System.
Chec
k the timer type of the
spe
cified journal group.
W
0
6505 58 620
The status of the extended
consistency g roup (EXCTG)
is changing. Wait for a
while, refresh the window,
and then retry the operation.
Wait for a while, refresh the
window, an d then retry the
operation.
W
0
6505 58 621
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the attribute of the
specified journal group is
invalid.
Check the attribute of the
specified journal group.
W
0
6505 58 624
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the combination of
the serial number and the
command device is invalid.
Check whether the specified
command device of the
specified serial number
exists.
W0
6505 58 62 5
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the specified
journal groups are being
used by another program
product.
Check whether the specified
journal group is being used
by other program product
which you use .
W
0
Remote Web Console error codes