HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)

Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6505 58 603
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the number of
journal groups in the EXCTG
exceeds the maximum.
Check the number of journal
groups in the specied
extended consistency group
(EXCTG).
W
0
6505 58 604
The specied journal group
is already registered to the
extended consistency group
(EXCTG) .
Check the journal groups
in the specied extended
consistency group (EXCTG).
W0
6505 58 605
Journal gro
ups cannot be
added to th
e extended
consisten
cy group (EXCTG),
because the sp ecied mirror
ID was different from the
mirrorIDwhichexistsinthe
EXCT G.
Check the mirr or ID of
the specied extended
consistency group (EXCTG).
W
0
6505 58 606
Journal groups cannot be
deleted from the extended
consistency group (EXCTG),
because the specied
EXCT G was not registered.
Check the status of
the specied extended
consistency group (EXCTG).
W
0
6505 58 607
Journal groups cannot be
deleted from the extended
consistency group (EXCTG),
because the specied
journal group was not
registered.
Check the journal groups in
the specied extended CT
group.
W
0
6505 58 608
The
Resume Pa ir operation
fai
led. The primary
sub
system does not support
th
eextendedCTgroup
(EXCTG) function, though
the restore journal group
belongs to an EXCTG.
Upd
atethemicrocodeofthe
pr
imary storage sy stem to
th
eversionwhichsupports
th
eEXCTGfunction.
W
0
6505 58 609
The timer type cannot
be changed because the
specied journal group
belongs to an extended
consistency group (EXCTG).
Check that the specied
journal group belongs to an
extended consistency group
(EXCTG).
W
0
6505 58 610
The parameter specied in
the extended consistency
group (EXCTG) operation is
invalid.
Refresh the window, and
then retry the op eration. If
this problem persists, call
technical suppor t.
W0
6505 58 611
The specied operation
failed because the
micropr ogram exchange
wasinprogressonthe
subsystem in the extended
consistency group (EXCTG).
Retry the operation after
the microcode exchange
completes.
W
0
6505 58 612
The previously executed
update processing of the
extended consistency group
(EXCTG) has not completed.
Please wait for a while, and
then retry the operation.
Please wait for a while, and
then retry the operation.
W
0
258