HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6505 58 592
The specified operation
failed because the
subsystem was being
powered on or powered off.
Check the status of the
storage system. Retry the
operation after the storage
system has started.
W0
6505 58 59 3
A communication time-out
error occurred in the
subsystem. If this message
isdisplayedafterasetting
operation, refresh the pa nel
and confirm whether the
setting is maintained. When
the set ting is not maintained,
retry the operation.
If this message is displayed
after a setting operation,
refresh the panel and
confirm whether the setting
is maintained. When the
setting is not maintained,
retry the operation.
W0
6505
58594
The Paircreate operation
failed because the
configuration of the LUSE
volume w
as different
between
the primary data
volume a
nd the secondary
data vo
lume.
Check the LUSE volume
configuration of the primary
data volume and the
secondary data volume.
W
0
6505 58 59 5
The Paircreate operation
failed because the
Continuous Access Journal
function of the secondary
subsystemdoesnotsupport
LUSE volumes.
Check whether the
Continuous Access Journal
function of the secondary
storage system supports
LUSE volumes.
W0
6505 58 59 6
Apairwhichisreadyfor
Delta resync cannot b e
created because At-Time
Split is set to the specified
restore journal group.
Check whether At-Time
Split is set to the specified
restore journal group by
using Business Continuity
Manager.
W
0
6505 58 597
Jou
rnal groups cannot be
add
ed to the extended
co
nsistency group (EXCTG),
because the controller ID of
the specified serial number
is invalid.
Check t he controller ID of
the specified serial number.
W
0
6505 58 600
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the Universal
Replicator for Mainframe
function is not installed.
Set the license of Universal
Replicator for Mainframe.
W
0
6505 58 601
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the additional
shared memory was not
installed.
Please call technical support
and install additional shared
memory.
W
0
6505 58602
Journal groups cannot be
added to the extended
consistency group (EXCTG),
because the number of
subsystems in the EXCTG
exceeds the maximum.
Check the number of storage
systems in the specified
extended consistency group
(EXCTG).
W
0
Remote Web Console error codes