HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6505 582 72
AConcurrentCopy
operation is in progress
on the specified secondar y
data volume.
Check the status of the
specified secondar y data
volume.
i
0
6505 582 73
The specified secondary
data volume belongs to
an access group or a pool
group of Volume Security.
Use Volume Security to
check the status of the
specified secondar y data
volume.
i
0
6505 582 75
The specified restore journal
group is not registered.
Check the specified restore
journal group.
i
0
6505 582 76
The specified secondary
data volumes cannot be
paired with another volume,
because the secondary data
volume is used as a journal
volume.
Check the status of the
specified secondar y data
volume.
i
0
6505 582 77
The specified secondary
data volume is not registered
in the specified journal
group.
Check data volumes in the
specified secondary journal
group.
i
0
6505 582 78
The specified restore journal
group is not registered.
Check th
estatusofthe
specifie
drestorejournal
group.
i
0
6505 582 79
The emulation type of the
specified secondary data
volume and the restore
journal volume is incorrect
due to one of the following
reasons:
• The emulation type is not
supported.
• The combination of
emulation types within
the journal group is
incorrect.
• The combination of
the emulation types
of the journal volumes
of the master and
restore journal groups is
incorrect.
• The emulation types
of the primary and
secondary data volumes
arenotthesame.
Check the emulation type
of the specified secondary
data volume or the restore
journal volume.
i
0
6505 58280
The specified secondary
data group is already
registered.
Check the status of the
specified secondar y data
volume.
i
0
6505 58281
No more pairs can be
registered in the specified
restore journal group.
Check the number of pairs
in the specified restore
journal group.
i
0
6505 58282
The specified secondary
data volume is already
registered in another journal
group.
Identify the journal group
where the specified
secondary data volume
is registered.
i
0
Remote Web Console error codes