HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recomme n ded Ac tio n
Severity
Level
Failure
Level
6505 87 20
The number of registered
remote subsystems already
reached the maximum (that
is, 64).
Reduce the number of
registered remote storage
systems, and then retry the
operation.
i
4
6505 87 21
Path creation has not
finished yet.
Check the path connections
between the local and the
remote storage systems, and
then retry the operation.
E
4
6505 87 22
Path creation failed.
Check the path connections
between the local and the
remote storage systems, and
then retry the operation.
E
4
6505 87 23
The Edit Path operation
was rejected because the
specified path is the last
path of some Continuous
Access pairs.
Add another path, o r delete
all pairs on the remote
storage system. After that,
retry the operation.
i
4
6505
8724
The specified number of
pathsislessthanthe
minimum number specified
in the DKC Option window.
Check the number of paths.
i
4
6505 87 27
The number of minimum
pathsexceedsthenumber
of normal paths.
Do eithe
r of the following to
recover from the error:
• If the error code is 100c,
add normal paths, and
then set the minimum
number of paths.
• If the error co de is 100d,
add normal paths,
and then delete paths.
Alternatively, reduce
the minimum number of
paths, and then delete
paths.
i
4
6505 87 28
The number of minimum
pathsexceedsthenumber
of normal paths.
Do either of the following to
recover from the error:
• If the error code is 100c,
add normal paths, and
then set the minimum
number of paths.
• If the error co de is 100d,
add normal paths,
and then delete paths.
Alternatively, reduce
the minimum number of
paths, and then delete
paths.
i
4
6505 87 2 9
An internal error occurred.
Please check the SSB log,
and then call technical
support.
E
4
230
HP StorageWorks XP Remote Web Console for Storage System M essages and Error Codes