HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6505 8705
The path could not
be deleted due to a
communication error
between the local and
theremotesubsystems.
Please check the CHA status
on the window. If the CHA
is blocked, replace the
CHA, and then retry the
operation.
W4
6505 8706
Parameter specified
by Continuous Access
operation is invalid.
Enter the correct data.
i
4
6505 8708
The pair sta
tus of the
secondary d
ata volume is
incorrect.
Please refre
sh the window,
and then che
ck the pair
status. If p
ossible , retry the
operation o
n the secondary
data volum
e.
i
4
6505 8709
Continuous Access
operation was rejected.
Please replace the channel
adapter, and then retry the
operation.
E
4
6505 8710
The pair status of the
specified data volume is
incorrect.
Please refresh the window
and check the pair status of
the pair. If the pair status
can be manipulated, retry
the operation.
W
0
6505 8711
The specified parameter is
incorrect.
Check th
eportnumber,ID,
and LUN
of the storage
system
.
i
4
6505 8712
The op eration was rejected
due to a FREEZE state.
If you are performing a
path operation, retry the
operation after the FREEZE
status is released.
If you are performing a pair
operation, check the DKC
status, wait until the SCP
time elapses, and then retry
the operation.
E
4
6505 8713
The port group already
exists on the specified port.
Please exchange the port
type after deleting the group
setting.
E
4
650
5
87 14
An internal error occurred. Please call technical support.
E
4
6505 8715
The number of paths is
incorrect.
Ensure that the number
of paths is correct, and
then retry the operation. If
the problem persists, call
technical support.
E
4
6505 8719
Theserialnumberorthe
controller ID of the remote
subsystemisincorrect.
Check the serial number
and the controller ID of this
remote storage system and
already registered remote
storage systems, and then
specify the correct values.
If the specified values
are correct, check the
cable connection of the
remote storage system. If
the problem persists, call
technical support.
E
4
Remote Web Console error codes