HP StorageWorks Remote Web Console error codes for XP12000/XP10000 Disk Arrays and SVS200 (AE002-96034, October 2007)
Part
Code
Error
Number
Error M essage
Recommended Ac tion
Severit y
Level
Failure
Level
6005 8817
Preset Suspension is effective
in the CT Group.
Cancel the preset
suspension in the CT
group, and then retry the
operation.
i
4
6005 8818
Preset Suspension is effective
in the CT Group.
Cancel the preset
suspension in the CT
group, and then retry the
operation.
i
4
6005 8819
Avolumecan
not be used as
an R-VOL whe
n:
• it is in an
intervent
ion-required
condition
.
• it is in a p
rotection
conditio
n.
• it is in u
nusable
conditi
on.
• it is a se
condary volume
of Busi
ness Copy or
atarge
tvolumeof
ShadowImage for
Mainf
rame.
• it is a
reserved volume
of Bu
siness Copy or
Shad
owImage for
Mainframe.
• it is a volume reserved
by Auto LUN.
• it is used by Universal
Replicator for
Mainframe.
Select another volume.
W4
6005 8820
The specified R-VOL is not
apermissibleconditionof
Continuous Access.
The Continuous Access
operation failed, because
R-VOL has one of the
following conditions:
1. Thevolumeisblocked.
2. Thevolumeisunder
maintenance.
3. The volume is copying
data (correction copy
or drive copy)
4. Thevolumeisinthe
correction access
condition.
W4
6005 8821
The spec ified R-VOL is
not recognizable from the
connection port.
Verify the configuration of
the specified R-VOL.
W4
6005 8822
An I/O Error occurred on
the R-VOL, or the R-VOL is in
an unusable c ondition.
Check whether the volume
is in a usable condition. If
thevolumeisusable,call
technical support.
E
4
Remote Web Console error codes